摘要

In this report, we propose a new method for measuring the nonlinear refractive index in liquid and glass samples using femtosecond (fs)-laser pulses with high pulse repetition rates. This method is based on solving the heat equation to derive an expression for the normalized transmittance of closed-aperture Z-scan measurements as a function of the accumulative thermal lens induced by a high-repetition-rate fs laser pulse. To validate this method, the nonlinear refractive indices of acetone as a liquid and soda-lime as a glass material have been measured using a 100 fs pulse duration, 80 MHz repetition rate, and 800 nm wavelength. The extracted nonlinear refractive index is in a good agreement with the reported one using 1 kHz repetition rate fs laser pulses. (C) 2019 Optical Society of America
机译:在本报告中,我们提出了一种用于使用具有高脉冲重复率的飞秒(FS)-Laser脉冲来测量液体和玻璃样品中的非线性折射率的新方法。 该方法基于求解热方程来导出闭孔Z扫描测量的归一化透射率的表达式作为由高重复率FS激光脉冲引起的累积热透镜的函数。 为了验证该方法,使用100 fs脉冲持续时间,80MHz重复率和800nm波长测量作为玻璃材料作为玻璃材料的丙酮作为液体和钠石灰的非线性折射率。 提取的非线性折射率与使用1kHz重复率FS激光脉冲的报告的非线性折射率良好。 (c)2019年光学学会