When rays are traced through an optical system, it is generally desired to send a ray from a specific object point through a specific point on the aperture stop. For retationally symmetric systems,-it is common to replace the aperture step itself by the Gaussian entrance pupil. The analog for this procedure is described here for the case of asymmetric systems. This first-order procedure for determining the initial configuration of a ray can be supplemented by a method that adds a second-order correction. This second-order method, which typically yields better estimates for initial ray configurations, is also described. Examples illustrating the use of these methods are given. # 1997 Optical Society of America [S0740-3232(97)01012-0]
机译:当光线通过光学系统追踪时,通常希望通过孔径停止的特定点从特定对象点发送射线。 对于定性对称的系统, - 通常是通过高斯入口瞳孔替换孔径步骤。 此处描述了该过程的模拟用于不对称系统的情况。 用于确定射线的初始配置的该第一阶方法可以由添加二阶校正的方法补充。 还描述了该二阶方法,其通常产生更好地估计初始光线配置。 说明给出了这些方法的使用的实例。 #1997年光学学会[S0740-3232(97)01012-0]