首页> 外文期刊>Journal of synchrotron radiation >Comparative analysis of sample preparation protocols of soft biological tissues for morphometric studies using synchrotron-based X-ray microtomography
【24h】

Comparative analysis of sample preparation protocols of soft biological tissues for morphometric studies using synchrotron-based X-ray microtomography

机译:基于同步辐射的X射线显微镜监测的不同生物组织样品制备方案的对比分析

获取原文
获取原文并翻译 | 示例
           

摘要

The spread of microtomography as a tool for visualization of soft tissues has had a significant impact on a better understanding of complex biological systems. This technique allows a detailed three-dimensional quantitative view of the specimen to be obtained, correlating its morphological organization with its function, providing valuable insights on the functionality of the tissue. Regularly overlooked, but of great importance, proper sample mounting and preparation are fundamental for achieving the highest possible image quality even for the high-resolution imaging systems currently under development. Here, a quantitative analysis compares some of the most common sample-mounting strategies used for synchrotron-based X-ray microtomography of soft tissues: alcoholic-immersion, paraffin-embedding and critical-point drying. These three distinct sample-mounting strategies were performed on the same specimen in order to investigate their impact on sample morphology regardless of individual sample variation. In that sense, the alcoholic-immersion strategy, although causing less shrinkage to the tissue, proved to be the most unsuitable approach for a high-throughput high-resolution imaging experiment due to sample drifting. Also, critical-point drying may present some interesting advantages regarding image quality but is also incompatible with a high-throughput experiment. Lastly, paraffin-embedding is shown to be the most suitable strategy for current soft tissue microtomography experiments. Such detailed analysis of biological sample-mounting strategies for synchrotron-based X-ray microtomography are expected to offer valuable insights on the best approach for using this technique for 3D imaging of soft tissues and following morphometric analysis.
机译:MicrotopRography作为用于可视化软组织的工具的传播对更好地理解复杂的生物系统具有显着影响。该技术允许获得样本的详细三维定量视图,将其形态组织与其功能相关联,为组织的功能提供有价值的见解。定期忽略,但具有重要的重要性,适当的样品安装和准备是实现最高可能的图像质量的基础,即使对于目前正在开发的高分辨率成像系统也是如此。这里,定量分析比较了用于软组织的Syschrootron的X射线微观图的一些最常见的样品安装策略:含酒精,嵌入的石蜡嵌入和临界点干燥。在相同的样本上进行这三种不同的样品安装策略,以便探讨它们对样品形态的影响,而不管单独的样本变异如何。从这种意义上讲,含酒精浸渍策略虽然导致组织的收缩较少,但被证明是由于样品漂移引起的高通量高分辨率成像实验最不合适的方法。此外,关键点干燥可能对图像质量产生一些有趣的优点,但也与高通量实验不相容。最后,将石蜡嵌入被证明是最适合当前软组织MICROROMOMATOM实验的策略。这种详细分析了同步基于同步的X射线微观图谱的策略分析,可以提供对使用该技术的软组织3D成像的最佳方法的有价值的见解,并在不同的情况下进行不同的分析。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号