首页> 外文期刊>Journal of the Korean Physical Society >The Image Evaluation of Iterative Motion Correction Reconstruction Algorithm PROPELLER T2-Weighted Imaging Compared with MultiVane T2-Weighted Imaging
【24h】

The Image Evaluation of Iterative Motion Correction Reconstruction Algorithm PROPELLER T2-Weighted Imaging Compared with MultiVane T2-Weighted Imaging

机译:迭代运动校正重建算法螺旋桨T2加权成像的图像评估与多功能T2加权成像相比

获取原文
获取原文并翻译 | 示例
           

摘要

The purpose of this study was to evaluate the usefulness and clinical applications of MultiVaneXD which was applying iterative motion correction reconstruction algorithm T2-weighted images compared with MultiVane images taken with a 3T MRI. A total of 20 patients with suspected pathologies of the liver and pancreatic-biliary system based on clinical and laboratory findings underwent upper abdominal MRI, acquired using the MultiVane and MultiVaneXD techniques. Two reviewers analyzed the MultiVane and MultiVaneXD T2-weighted images qualitatively and quantitatively. Each reviewer evaluated vessel conspicuity by observing motion artifacts and the sharpness of the portal vein, hepatic vein, and upper organs. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated by one reviewer for quantitative analysis. The interclass correlation coefficient was evaluated to measure inter-observer reliability. There were significant differences between MultiVane and MultiVaneXD in motion artifact evaluation. Furthermore, MultiVane was given a better score than MultiVaneXD in abdominal organ sharpness and vessel conspicuity, but the difference was insignificant. The reliability coefficient values were over 0.8 in every evaluation. MultiVaneXD (2.12) showed a higher value than did MultiVane (1.98), but the difference was insignificant (p = 0.135). MultiVaneXD is a motion correction method that is more advanced than MultiVane, and it produced an increased SNR, resulting in a greater ability to detect focal abdominal lesions.
机译:本研究的目的是评估MultiVanexd的用性和临床应用,其与用3T MRI拍摄的多膜图像相比,该多兰德的应用迭代运动校正重建算法T2加权图像。基于临床和实验室发现的肝癌和胰胆道系统共有20例患者,使用多糖和多葡糖技术获得上腹部MRI。两个审阅者定性和定量地分析了多曲线和多瓦斯克T2加权图像。每次审阅者通过观察运动伪影和门静脉,肝静脉和上器官的锐度来评估容器肢体。通过一个审查员计算信噪比(SNR)和对比度 - 噪声比(CNR)进行定量分析。评估杂交相关系数以测量观察者间可靠性。多曲线和多瓦克斯在运动伪影评估中存在显着差异。此外,多种遗物在腹部器官锐度和船舶阴谋中获得比多葡糖更好的分数,但差异是微不足道的。每次评估中可靠性系数值超过0.8。 MultivanexD(2.12)显示出比多膜(1.98)的值较高,但差异是微不足道的(P = 0.135)。 MultiVanexd是一种比多膜更先进的运动校正方法,它产生了增加的SNR,导致较大的检测局灶性腹部病变的能力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号