首页> 外文期刊>Journal of the European Ceramic Society >Fracture toughness testing of biomedical ceramic-based materials using beams, plates and discs
【24h】

Fracture toughness testing of biomedical ceramic-based materials using beams, plates and discs

机译:使用梁,板和椎间盘进行生物医学陶瓷基材料的断裂韧性测试

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

The testing of fracture toughness becomes problematic when only limited amount of material is available that hinders the production of typical beam specimens to be tested in bending. Here we explore fracture toughness testing methodologies that allow for small discs and plates having surface cracks to be tested in biaxial flexure using the Ball-on-3-balls (B3B) set-up, or sawed notches as in the Compact Tension geometry. The B3B-K-Ic test has shown to be versatile and account for a very small overestimation of the K-Ic-value in the order of 0.8-1.25% due to in-plane crack mispositioning, and a maximum of 4% if a worst-case scenario of additional out-of-plane mispositioning is assumed. The geometrical factor in the standard SCF method, derived by Newman and Raju, resulted in an overestimation of similar to 8% of the K-Ic-value compared to the new calculation by Strobl et al. for materials with Poisson's ratio 0.3.
机译:当只有有限量的材料可用时,裂缝韧性的测试变得有问题,即阻碍待弯曲的典型光束试样的生产。 在这里,我们探索骨折韧性测试方法,其允许在使用球上的3 - 球(B3b)设置的双轴弯曲中具有表面裂缝的小盘和板,或者在紧凑的张力几何形状中锯切凹口。 B3B-K-IC测试已被通用,并且由于面内裂纹失误而大约为0.8-1.25%的k-ic值的大估计值,最多4% 假设额外的面外失值的最坏情况。 由Newman和Raju衍生的标准SCF方法的几何因素导致与TroBl等人的新计算相比,高估了与K-IC值的8%。 对于具有泊松比率的材料& 0.3。

著录项

  • 来源
  • 作者单位

    Friedrich Alexander Univ Erlangen Nurnberg FAU Zahnklin Zahnerhaltung &

    Parodontol 1 Forchungslab Dent Biomat Glueckstr 11 D-91054 Erlangen Germany;

    Friedrich Alexander Univ Erlangen Nurnberg FAU Zahnklin Zahnerhaltung &

    Parodontol 1 Forchungslab Dent Biomat Glueckstr 11 D-91054 Erlangen Germany;

    Friedrich Alexander Univ Erlangen Nurnberg FAU Zahnklin Zahnerhaltung &

    Parodontol 1 Forchungslab Dent Biomat Glueckstr 11 D-91054 Erlangen Germany;

    Univ Leoben Inst Struktur &

    Funktionskeram A-8700 Leoben Austria;

    Friedrich Alexander Univ Erlangen Nurnberg FAU Zahnklin Zahnerhaltung &

    Parodontol 1 Forchungslab Dent Biomat Glueckstr 11 D-91054 Erlangen Germany;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 陶瓷工业;
  • 关键词

    Dental; Ceramics; Composites; Fracture toughness; Testing;

    机译:牙科;陶瓷;复合材料;断裂韧性;测试;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号