首页> 外文期刊>Journal of strength and conditioning research >Test-Retest Reliability of a Commercial Linear Position Transducer (GymAware PowerTool) to Measure Velocity and Power in the Back Squat and Bench Press
【24h】

Test-Retest Reliability of a Commercial Linear Position Transducer (GymAware PowerTool) to Measure Velocity and Power in the Back Squat and Bench Press

机译:测试 - 重新测试商用线性位置换能器(Gymaware Powertool)的可靠性,以测量后蹲和卧床的速度和电力

获取原文
获取原文并翻译 | 示例

摘要

Orange, ST, Metcalfe, JW, Marshall, P, Vince, RV, Madden, LA, and Liefeith, A. Test-retest reliability of a commercial linear position transducer (GymAware PowerTool) to measure velocity and power in the back squat and bench press. J Strength Cond Res 34(3): 728-737, 2020-This study examined the test-retest reliability of the GymAware PowerTool (GYM) to measure velocity and power in the free-weight back squat and bench press. Twenty-nine academy rugby league players (age: 17.6 +/- 1.0 years; body mass: 87.3 +/- 20.8 kg) completed 2 test-retest sessions for the back squat followed by 2 test-retest sessions for the bench press. GYM measured mean velocity (MV), peak velocity (PV), mean power (MP), and peak power at 20, 40, 60, 80, and 90% of 1 repetition maximum (1RM). GYM showed good reliability (intraclass correlation coefficient [ICC] and standard error of measurement percentage, respectively) for the measurement of MV at loads of 40 (0.77, 3.9%), 60 (0.83, 4.8%), 80 (0.83, 5.8%), and 90% (0.79, 7.9%) of 1RM in the back squat. In the bench press, good reliability was evident for PV at 40 (0.82, 3.9%), 60 (0.81, 5.1%), and 80% (0.77, 8.4%) of 1RM, and for MV at 80 (0.78, 7.9%) and 90% (0.87, 9.9%) of 1RM. The measurement of MP showed good to excellent levels of reliability across all relative loads (ICC >= 0.75). In conclusion, GYM provides practitioners with reliable kinematic information in the back squat and bench press, at least with loads of 40-90% of 1RM. This suggests that strength and conditioning coaches can use the velocity data to regulate training load according to daily readiness and target specific components of the force-velocity curve. However, caution should be taken when measuring movement velocity at loads <40% of 1RM.
机译:Orange,St,Metcalfe,JW,Marshall,P,Vince,RV,Madden,La和La和Liefith,A.测试 - 重新测试商业线性位置传感器(Gymaware Powertool)的可靠性,以测量后蹲和长凳的速度和电力按。 J Fircience Cond Res 34(3):728-737,2020-本研究检测了The Gymaware Powertool(健身房)的测试保持可靠性,以测量自由重重蹲和台式压力机中的速度和功率。二十九届学院橄榄球联盟球员(年龄:17.6 +/- 1.0岁;体重:87.3 +/- 20.8 kg)完成了2个测试 - 重新测试的后蹲接,后跟2个测试重新测试的床位。健身房测量平均速度(MV),峰值速度(PV),平均功率(MP),以及20,40,60,80和90%的峰值功率最大值(1RM)。健身房表现出良好的可靠性(分别为MV的MV测量良好的可靠性(分别是测量百分比的标准误差)40(0.77,3.9%),60(0.83,4.8%),80(0.83,5.8% )和后蹲90%(0.79,7.9%)1RM。在台式压力机中,PV的良好可靠性在40(0.82,3.9%),60%(0.81,5.1%)和80%(0.77,8.4%)的1RM,80%(0.78,7.9%) )和90%(0.87,9.9%)1RM。 MP的测量显示出所有相对载荷的优异可靠性良好(ICC> = 0.75)。总之,健身房为从业者提供了后蹲和台式压力机中可靠的运动信息,至少负载为1毫升的40-90%。这表明强度和调节教练可以使用速度数据根据每日准备度和力速度曲线的特定组件来调节训练负载。但是,在载荷的移动速度<40%的1RM时,应注意谨慎。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号