首页> 外文期刊>Journal of radiological protection: Official journal of the Society for Radiological Protection >Strategies to optimise occupational radiation protection in interventional cardiology using simultaneous registration of patient and staff doses
【24h】

Strategies to optimise occupational radiation protection in interventional cardiology using simultaneous registration of patient and staff doses

机译:使用患者和人员剂量同时登记优化介入心脏病学中职业辐射保护的策略

获取原文
获取原文并翻译 | 示例
       

摘要

The International Commission on Radiological Protection recommends that occupational protection and patient protection be managed in an integrated approach. This paper describes the experience and the initial results of a system able to register and to process simultaneously staff and patient doses in interventional cardiology and the practical use of this system in the optimisation of occupational exposure. The system used simultaneously collects and manages patient and staff doses for all radiation events. The personal electronic dosimeters worn over the protective apron of health professionals working inside catheterisation laboratories can send (wireless) doses and dose rate values to an X-hub and provide the operators inside the catheterisation rooms with real-time information. Individual and global reports for all the health professionals may be periodically obtained from the system to help with the optimisation. The results for eight cardiologists, one fellow and four nurses for a total of 2468 interventional cardiology procedures and 3207 occupational dose values collected over one year are presented here. Annual doses Hp(10) measured over the apron for cardiologists ranged from 0.3 to 6.3 mSv. For the cardiologist, the ratio between occupational doses (over the apron) and patient doses ranged from 0.05 to 0.23 mu Sv Gy(-1) cm(-2), with a mean value of 0.12 mu Sv Gy(-1) cm(-2). The system allows defining optimisation strategies by comparing the results between the different operators while considering the workload and complexity of the procedures (based on the total Kerma Area Product managed by the different operators). The registration of the date and time of the occupational radiation doses allows auditing the use of the personal dosimeters worn by the various operators.
机译:国际放射保护委员会建议以综合方法管理职业保护和患者保护。本文介绍了能够在介入心脏病学中同时注册和加工员工和患者剂量的系统的经验和初始结果,并在职业暴露的优化中进行该系统的实际应用。用于所有辐射事件的系统同时使用和管理患者和员工剂量。在导管实验室内工作的保健专业人员的保护围裙穿过的个人电子剂量计可以向X-Hub发送(无线)剂量和剂量率值,并在导管内的操作员提供实时信息。所有卫生专业人员的个人和全球报告都可以从系统中定期获得以帮助优化。八位心脏病学家的结果,这里的一名和四名护士共2468个介入心脏病学程序和3207年收集的3207个职业剂量值。每年剂量HP(10)在围裙上测量的心脏病学家的测量范围为0.3至6.3 msv。对于心脏病学家,职业剂量(围绕)和患者剂量之间的比率范围为0.05至0.23μsvγ(-1)cm(-2),平均值为0.12μmsvgy(-1)cm( -2)。该系统允许通过比较不同运营商之间的结果来定义优化策略,同时考虑程序的工作量和程序的复杂性(基于不同运算符管理的总Kerma区域产品)。职业辐射剂量的日期和时间的登记允许审核各种运营商穿的个人剂量计。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号