首页> 外文期刊>Journal of Reinforced Plastics and Composites >Providing a model for estimating the compressive strength of square and rectangular columns confined with a variety of fibre-reinforced polymer sheets
【24h】

Providing a model for estimating the compressive strength of square and rectangular columns confined with a variety of fibre-reinforced polymer sheets

机译:提供一种估计方形和矩形柱抗压强度的模型,包括各种纤维增强的聚合物片

获取原文
获取原文并翻译 | 示例
           

摘要

One of the most common ways of strengthening the columns is the confinement of the reinforced concrete columns. So far, several experiments have been conducted on concrete columns confined with fibre-reinforced polymer sheets and the results show that the use of fibre-reinforced polymer sheets increases the compressive strength of the concrete columns effectively. Different models in order to determine the compressive strength of the fibre-reinforced-polymer-confined concrete columns are provided in the previous researches. In this study, a wide range of experimental data for square and rectangular columns confined with a variety of fibre-reinforced polymer sheets has been collected. In order to increase the accuracy in the existing models, a modified model for predicting the compressive strength of square and rectangular columns confined with different fibre-reinforced sheets has been proposed by using the collected data. In the current study, the fibre-reinforced polymer strain efficiency factor and the section shape factor are composed and considered as a unique factor. Considering the fibre-reinforced polymer hoop strain concentration at the affected area including the corners area and the surrounding area of them, this factor has been adopted as a fibre-reinforced polymer averaged hoop strain factor for the whole circumference of the section. Based on the published experimental data, a comparison between the analytical results obtained with the present model and the results of the other models, shows considerably betterresults of the proposed model described in this study. Moreover, application of the proposed model for behaviour prediction of concrete-filled fibre-reinforced polymer tubes is evaluated in this study and the results show that the proposed model is more accurate than the other models.
机译:强化柱最常见的方法之一是钢筋混凝土柱的限制。到目前为止,已经在混凝土柱上进行了几个实验,限制了纤维增强的聚合物片,结果表明,使用纤维增强聚合物片材有效地增加了混凝土柱的压缩强度。在先前的研究中提供了不同的模型以确定纤维增强聚合物密闭的混凝土柱的抗压强度。在该研究中,已经收集了广场和矩形柱的各种实验数据,其限制了各种纤维增强聚合物片。为了提高现有模型中的准确性,通过使用收集的数据提出了一种用于预测与不同的纤维增强薄片限制的正方形和矩形柱的压缩强度的改进模型。在目前的研究中,纤维增强的聚合物应变效率因子和截面形状因子被组成并被认为是独特的因子。考虑到包括拐角区域和它们的周围区域在内的受影响区域的纤维增强聚合物箍应变浓度,该因子已被采用作为该截面的整个圆周的纤维增强聚合物平均环荷应变因子。基于已发布的实验数据,利用本模型获得的分析结果与其他模型的结果进行比较,表明了本研究中描述的所提出的模型的显着更好。此外,在本研究中评估了应用混凝土纤维增强聚合物管的所提出的行为预测模型,结果表明,该模型比其他模型更准确。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号