Background Use of technology capable of electromagnetically tracking advancement of a feeding tube on a monitoring screen during insertion may enable detection of deviation of the tube from the midline as it advances through the chest, possibly indicating entry of the tube into the right or left main bronchus. Purposes To describe (1) published peer-reviewed studies that report on the detection of malpositioned tubes inserted by an electromagnetic tube placement device, and (2) events reported to the US Food and Drug Administration''s Manufacturer and User Facility Device Experience (MAUDE) database regarding use of such a device. Methods An Ovid MEDLINE search was conducted to locate peer-reviewed studies published between 2007 and 2012 that referred to use of an electromagnetic tube placement device to detect inadvertent respiratory placements of feeding tubes. In addition, an online search of the MAUDE database was conducted for the years 2007 through 2012. Results The Ovid MEDLINE search yielded 6 studies that referred to respiratory placements; no cases of pneumothorax were reported. The MAUDE database search yielded 21 adverse events associated with use of an electromagnetic tube placement device (including 17 cases of pneumothorax and 2 deaths). As the MAUDE database relies on voluntary reports, this number should not be construed as the incidence of malpositioned tubes during this period. Conclusions The ability of clinicians to place feeding tubes correctly by using an electromagnetic tube placement device varies. Thus, it is reasonable to question the wisdom of eliminating radiographic confirmation of tube position before starting feedings.
机译:背景技术使用能够在插入过程中以电磁方式跟踪监视屏幕上的进料管前进的技术,可以检测到进出管穿过胸部时与中线的偏离,这可能表明进出管进入了右或左主支气管。目的描述(1)已发表的经过同行评审的研究,这些研究报告了由电磁管放置设备插入的位置不正确的管的检测,以及(2)报告给美国食品和药物管理局制造商和用户设施设备使用经验的事件( MAUDE)有关使用此类设备的数据库。方法进行Ovid MEDLINE搜索,以查找在2007年至2012年之间发表的同行评审研究,该研究涉及使用电磁管放置设备来检测喂养管的意外呼吸放置。此外,还对2007年至2012年之间的MAUDE数据库进行了在线搜索。结果Ovid MEDLINE搜索产生了6项涉及呼吸系统位置的研究。没有报告气胸病例。 MAUDE数据库搜索产生了与使用电磁管放置设备相关的21个不良事件(包括17例气胸和2例死亡)。由于MAUDE数据库依赖于自愿报告,因此不应将此数字解释为在此期间发生管子位置不正确的发生率。结论临床医生使用电磁管放置装置正确放置饲管的能力各不相同。因此,有理由质疑在开始喂食之前消除射线照相对管位置的确认是否明智。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号