Abstract Purpose To determine the accuracy of a digital manufacturing method for dental implant restorations on stock abutments using intraoral scanners and prefabricated stock‐abutment libraries. Materials and Methods Two dental implants with internal hexagonal connections were placed in the mandibular second premolar and second molar areas of a partially edentulous dentoform model; stock abutments with a diameter of 5 mm, abutment height of 5.5 mm, and gingival cuff height of 2 mm were connected. The study model was scanned 10 times using a reference tabletop scanner and 5 types of intraoral scanners (IOSs). The data collected by 5 types of IOSs were divided into 3 groups, based on the type and matching of stock abutment library data: no library, optical library, and contact library groups. A total of 160 data files were analyzed, including reference data. The resulting data were used to evaluate trueness and precision. Results Trueness and precision values in the group in which library data of the stock abutment were not used were 42.0 to 76.3 μm and 30.5 to 99.7 μm; corresponding values when the library data using an optical scanner were matched were 51.2 to 73.4 μm and 26.3 to 62.8 μm, and those when contact scanner library data were used were 30.1 to 62.4 μm and 15.5 to 55.9 μm. Thus, the accuracy of the contact library group was significantly higher than the accuracies of the no library ( p 0.001) and optical library groups ( p 0.001). Conclusion The application of prefabricated library data of stock abutments using a contact scanner improved the accuracy of scan data. Scan accuracy of the stock abutments differed significantly based on the type of scanner.
机译:摘要目的,用于确定牙科扫描仪对牙科植入物修复的数字制造方法的准确性,采用口腔扫描仪和预制的库存基库库。材料和方法具有内部六边形连接的两种牙科植入物置于颗粒的颌骨第二磨牙和第二磨牙区域的部分透明的牙本质模型;直径为5毫米,邻接高度为5.5毫米的托管台,连接2毫米的牙龈袖口高度。使用参考桌面扫描仪和5种类型的口腔扫描仪(IOSS)扫描研究模型。由5种IOSS收集的数据分为3组,基于库存邻接库数据的类型和匹配:没有库,光学库和联系库组。分析了总共160个数据文件,包括参考数据。由此产生的数据用于评估真实和精度。结果基团库数据中未使用库数据的基团的特殊和精度值为42.0至76.3μm,30.5至99.7μm;当使用光学扫描仪的库数据匹配时,相应的值为51.2至73.4μm,并且使用接触扫描仪库数据时,使用接触扫描仪库数据为30.1至62.4μm,15.5至55.9μm。因此,接触文库组的准确性显着高于NO文库(P <0.001)和光学库基团的精度(P <0.001)。结论使用联系人扫描仪应用预制库数据的应用程序数据提高了扫描数据的准确性。基于扫描仪的类型,扫描准确性的扫描精度有显着不同。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号