Therapeutic Efficacy of Twin-Block and Fixed Oral Appliances in Patients with Obstructive Sleep Apnea Syndrome

机译:阻塞性睡眠呼吸暂停综合征患者双嵌段和固定口腔用具的治疗疗效

获取原文
获取原文并翻译 | 示例

摘要

Purpose To compare the efficacy of twin-block (i.e., allows mouth opening) and fixed (i.e., maintains mouth closure) mandibular advancement splints (MASs) for the treatment of obstructive sleep apnea-hypopnea syndrome (OSA). Materials and Methods From 2011 to 2013, 23 patients with OSA in the twin-block group, and from 2013 to 2015, 29 patients in the fixed MAS group were included. All patients underwent polysomnography before and after 3 months of treatment. The two sets of polysomnographic and cephalometric variables were compared. Results A significant difference (p 0.001) was observed in the apnea-hypopnea index before and after MAS treatment in both groups (twin-block group: 20.6 +/- 11.5 vs. 14.7 +/- 9.4; fixed group: 21.4 +/- 15.2 vs. 11.2 +/- 9.7). In the twin-block group, 5 patients (21.7%) were complete responders, 9 (39.1%) were fair responders, and 9 (39.1%) were nonresponders; the corresponding figures for the fixed group were 14 (48.3%), 9 (31.0%), and 6 (20.7%) patients. A significant between-group difference was observed in the distribution of responders (p = 0.046). The fixed group showed a significant improvement in the snoring index (p = 0.003), arousal index (p = 0.036), and desaturation rate (p = 0.012). Finally, the change in incisal overjet was larger in the fixed group than in the twin-block group (p 0.001). Conclusions These results suggest that fixed oral appliances are superior in treating OSA, based on their ability to prevent mouth opening and reduce incisal overjet.
机译:为了比较双嵌段(即,允许嘴口)和固定(即,保持嘴闭嘴)下颌前进夹板(质量)的疗效进行比较,用于治疗阻塞性睡眠呼吸暂停症综合征(OSA)。 2011至2013年的材料和方法,23例OSA患者在双块组,2013年至2015年,包括固定MAS集团的29名患者。所有患者均在治疗3个月后和后经过多肌绪。比较了两套多瘤和头部测量变量。结果在两组的MAS治疗之前和之后在呼吸暂停治疗前后观察到显着差异(P <0.001)(双嵌段组:20.6 +/- 11.5与14.7 +/- 9.4;固定组:21.4 + / - 15.2与11.2 +/- 9.7)。在双嵌段组中,5名患者(21.7%)是完整的响应者,9名(39.1%)是公平的响应者,9名(39.1%)是非反应者;固定基团的相应图为14(48.3%),9(31.0%)和6名(20.7%)患者。在响应者的分布中观察到组差异显着(P = 0.046)。固定组在打鼾指数(P = 0.003),唤醒指数(P = 0.036)和去饱和率(P = 0.012)中显示出显着改善。最后,固定组中切牙超喷射的变化比双嵌段组更大(P <0.001)。结论这些结果表明,固定的口服电器在治疗OSA方面是优越的,这是根据其防止口腔开口和减少切割的能力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号