首页> 外文期刊>American journal of dentistry >Evaluation of the use of ultrasound within a power toothbrush to dislodge oral bacteria using an in vitro Streptococcus mutans biofilm model.
【24h】

Evaluation of the use of ultrasound within a power toothbrush to dislodge oral bacteria using an in vitro Streptococcus mutans biofilm model.

机译:使用体外变形链球菌生物膜模型评估电动牙刷内超声驱除口腔细菌的使用。

获取原文
获取原文并翻译 | 示例
       

摘要

PURPOSE: To investigate in vitro the use of ultrasound in a power toothbrush to aid in the removal of dental plaque biofilm without bristle contact. METHODS: Dental plaque was modeled using Streptococcus mutans biofilm adherent to hydroxyapatite disks. Treatment arms included positive and negative controls, disks with and without biofilm, respectively. Power toothbrush modes of action tested included a toothbrush with sonic and ultrasonic action (ULT), the same toothbrush with only sonic action (ULN), a sonic toothbrush (SON) and a rotating/oscillating toothbrush (OSC). The active element of the toothbrushes (bristles or point of ultrasound emission) was immersed in toothpaste slurry and held 3 mm away from the disk surface. Treatment included activation of the toothbrush mode of action for 5 seconds. Control disks were exposed to the same fluid environment but not exposed to a power toothbrush. After treatment, biofilm present on the disks was stained using a red dental plaque disclosing solution. Photographs were then taken and the presence of biofilm assessed using digital image analysis. For each disk a normalized pixel volume, related to the presence of biofilm corrected for lighting, was determined. Statistical testing was done with a one-way ANOVA and a Bonferroni post hoc test. RESULTS: Normalized pixel volumes (mean +/- standard deviation) were 0.428 (0.010) for the negative control and 1.022 (0.040) for the positive control. Normalized pixel volumes for the power toothbrush modes of action were 0.641 (0.075) for ULT, 0.972 (0.027) for ULN, 0.921 (0.010) for SON and 0.955 (0.025) for OSC. Statistical analysis showed a significant treatment effect (P<0.001). All power toothbrush modes of action exhibited some biofilm removal without bristle contact in this in vitro assay. Of the modes of action tested, the combined sonic and ultrasonic mode of action (ULT) removed the greatest amount of biofilm from the disk surfaces. The same toothbrush when tested with (ULT) and without (ULN) ultrasound showed a greater amount of biofilm removed when ultrasound was present.
机译:目的:研究超声在电动牙刷中的使用,以在不与刷毛接触的情况下帮助去除牙菌斑生物膜。方法:使用粘附在羟基磷灰石圆​​盘上的变形链球菌生物膜对牙菌斑进行建模。治疗组包括阳性和阴性对照,分别带有和不带有生物膜的盘片。测试的电动牙刷的作用方式包括具有声波和超声波作用的牙刷(ULT),仅具有声波作用的同一牙刷(ULN),声波牙刷(SON)和旋转/振荡牙刷(OSC)。将牙刷的活性成分(刷毛或超声波发射点)浸入牙膏浆中,并保持距牙盘表面3 mm的距离。治疗包括激活牙刷作用模式达5秒钟。控制盘暴露在相同的流体环境中,但没有暴露在电动牙刷中。处理后,使用红色牙菌斑披露溶液对存在于椎间盘上的生物膜进行染色。然后拍摄照片,并使用数字图像分析评估生物膜的存在。对于每个盘,确定与校正了照明的生物膜的存在有关的归一化像素体积。使用单向方差分析和Bonferroni事后检验进行统计检验。结果:阴性对照的标准化像素体积(平均+/-标准偏差)为0.428(0.010),而阳性对照为1.022(0.040)。电动牙刷作用模式的归一化像素体积(ULT)为0.641(0.075),ULN为0.972(0.027),SON为0.921(0.010),OSC为0.955(0.025)。统计分析表明有显着的治疗效果(P <0.001)。在该体外测定中,所有电动牙刷的作用方式均表现出一些生物膜去除作用,而没有刷毛接触。在测试的作用方式中,组合的声音和超声作用方式(ULT)从磁盘表面去除了最大量的生物膜。当使用(ULT)和不使用(ULN)超声进行测试时,相同的牙刷在存在超声时会清除更多的生物膜。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号