首页> 外文期刊>Journal of Performance of Constructed Facilities >Joint Response of Existing Pipe Culverts under Surface Live Loads
【24h】

Joint Response of Existing Pipe Culverts under Surface Live Loads

机译:表面活载下现有管道涵洞的关节响应

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

This study investigates the field performance of culvert joints in five existing pipe culverts. Test culverts consisted of two corrugated metal culverts, two reinforced concrete culverts, and one high-density polyethylene culvert. Culverts were selected for back-fill depths less than 1.5 m and inner diameters ranging from 0.9 to 2.1 m. Static loading was applied to the culverts by parking a heavily loaded truck at different positions above the culvert joint. Dynamic loading was applied by driving the truck over the culvert at speeds ranging from 8 to 48 km/h. Culvert deflections and strains were measured near one of the culvert's joints. Separation at the joint was also measured. The results indicate that separation at the joint was quite significant at times. In the worst case, the measured separation at the joint was equal to 50% of the measured deflection. Strains measured near the joint in steel culverts were significantly smaller than the yield strain. The dynamic deflections were typically 10-40% less than the static deflections. (C) 2014 American Society of Civil Engineers.
机译:本研究调查了五个现有管道涵洞中涵洞的现场性能。测试涵洞由两个波纹金属涵洞,两个钢筋混凝土涵洞和一个高密度聚乙烯涵洞组成。选择涵洞的后填充深度小于1.5米,内径范围为0.9至2.1μm。通过在涵洞上方的不同位置停车,将静态加载应用于涵洞。通过在8至48 km / h的速度范围内驾驶卡车在涵洞上驾驶卡车来应用动态载荷。涵洞偏转和菌株在涵洞的一个关节附近测量。还测量了关节的分离。结果表明关节的分离有时相当显着。在最坏的情况下,接头处的测量分离等于测量挠度的50%。在钢涵洞接头附近测量的菌株显着小于产率菌株。动态偏转通常比静态偏转小10-40%。 (c)2014年美国土木工程师协会。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号