This paper presents an assessment of postfire damage of a RC factory building. The fire was limited to the ground floor; thus, the structural elements on the ground floor were fire damaged. Also, some relative displacements were observed at the expansion joints, and long wall cracks were observed on other stories. During the visual assessment, typical fire damage was observed (e.g., spalling, netlike cracks, crumbled plaster, bared or visible reinforcement, and crumbled aggregates). Also, some explosive and thermal expansion-induced damage was observed in and out of the fire-damaged areas. To evaluate the effects of the fire on the concrete, spectrophotometer and compressive strength tests were performed on concrete specimens taken from the building. It is concluded that elevated temperatures due to a fire can cause damage in the fire region, and that it can affect the overall stability of the structure.
机译:本文提出了对RC工厂建筑的出发损坏的评估。 火灾仅限于底层; 因此,地板上的结构元素被损坏。 而且,在伸缩缝观察到一些相对位移,并且在其他故事中观察到长壁裂缝。 在视觉评估期间,观察到典型的火焰损坏(例如,剥落,网状裂缝,碎膏石膏,露出或可见的加固和粉碎的聚集体)。 此外,在火灾受损区域内观察到一些爆炸性和热膨胀诱导的损伤。 为了评估火灾对混凝土的影响,在从建筑物采集的混凝土标本上进行分光光度计和压缩强度试验。 结论是,由于火引起的升高的温度会导致火灾区域造成损坏,并且它会影响结构的整体稳定性。