ABSTRACT The primary stability achieved during total hip arthroplasty determines the long‐term success of cementless acetabular cups. Pre‐clinical finite element testing of cups typically use a model of a single patient and assume the results can be extrapolated to the general population. This study explored the variability in predicted primary stability of a Pinnacle ? cementless acetabular cup in 103 patient‐specific finite element models of the hemipelvis and examined the association between patient‐related factors and the observed variability. Cups were inserted by displacement‐control into the FE models and then a loading configuration simulating a complete level gait cycle was applied. The cohort showed a range of polar gap of 284–1112?μm and 95th percentile composite peak micromotion (CPM) of 18–624?μm. Regression analysis was not conclusive on the relationship between patient‐related factors and primary stability. No relationship was found between polar gap and micromotion. However, when the patient‐related factors were categorised into quartile groups, trends suggested higher polar gaps occurred in subjects with small and shallow acetabular geometries and cup motion during gait was affected most by low elastic modulus and high bodyweight. The variation in primary stability in the cohort for an acetabular cup with a proven clinical track record may provide benchmark data when evaluating new cup designs. ? 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:1012–1023, 2018.
机译:摘要总髋关节置换术期间达到的主要稳定性决定了无粘液髋臼杯的长期成功。杯子的临床前有限元试验通常使用单一患者的模型,并假设结果可以推断给一般人群。本研究探讨了巅峰预测的初级稳定性的可变性吗?浑浊的髋臼杯在103名患者特异性有限元模型的半屈普里斯和患者相关因素之间的关联和观察到的变异性。通过位移控制进入FE模型,然后施加模拟完整级别步态周期的加载配置。队列显示了极性间隙的范围为284-1112Ω·μm和95百分位复合峰值微调(CPM),为18-624ΩΩμm。回归分析不是关于患者相关因素与初级稳定性之间的关系的确定。在极隙和微观之间没有发现任何关系。然而,当患者相关的因子分为四分位数时,趋势表明,在具有小和浅髋臼几何形状的受试者中发生了更高的极性间隙,并且在步态期间的杯运动受到低弹性模量和高体重的影响。具有经过验证的临床轨迹记录的髋臼杯的队列中的初级稳定性的变化可以在评估新杯设计时提供基准数据。还2017年骨科研究会。由Wiley Hearyicals,Inc.J orthop Res 36:1012-1023,2018出版。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号