首页> 外文期刊>Journal of orthopaedic research >Contrast-enhanced CT of the intervertebral disc: A comparison of anionic and cationic contrast agents for biochemical and morphological characterization
【24h】

Contrast-enhanced CT of the intervertebral disc: A comparison of anionic and cationic contrast agents for biochemical and morphological characterization

机译:椎间盘的对比度增强CT:对生物化学和形态表征的阴离子和阳离子造影剂的比较

获取原文
获取原文并翻译 | 示例
           

摘要

The objective of this study was to quantify and compare the contrast-enhancing properties of the anionic contrast agent ioxaglate/Hexabrix, and cationic contrast agent CA(4+) for biochemical and morphological characterization of the intervertebral disc (IVD) via CT. Optimal contrast agent concentrations were determined by incubating rat lumbar IVDs in dilutions of Hexabrix-320 (20%, 30%, 40%, and 50%) and CA(4+) (10, 20, 30, and 40mgI/ml). CT imaging was performed at 70kVp, 114A, and 250ms integration time, 12m voxel size. The kinetics of contrast enhancement were quantified with cumulative incubations for 0.5, 1, 2, 12, 16, 20, and 24h using both agents. Agreement in morphological quantification was assessed via serial scans of the same IVDs. Correlation of attenuation to glycosaminoglycan (GAG) content was determined by enzymatic digestion of IVDs, subsequent CT imaging, and GAG quantification via dimethylmethylene blue assay. Forty percent Hexabrix and 30mgI/ml CA(4+) were chosen as optimal concentrations. Hexabrix enabled greater delineation of the IVD from surrounding tissues, and CA(4+) had the lowest uptake in surrounding soft tissue. Twenty-four hour incubation was sufficient for >99% equilibration of both agents. A high level of agreement was observed in the quantification of IVD volume (ICC=0.951, r=0.997) and height (ICC=0.947, r=0.991). Both agents exhibited strong linear correlations between CT attenuation and GAG content (Hexabrix: r=-0.940; CA(4+): r=0.887). Both agents enable biochemical and morphological quantification of the IVD via contrast-enhanced CT and are effective tools for preclinical characterization. (c) 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:1067-1075, 2017.
机译:本研究的目的是量化和比较阴离子造影剂IOxaglate / Hexabrix的对比度增强性能,以及通过CT的椎间盘(IVD)的生化和形态学表征的阳离子造影剂Ca(4+)。通过在稀释的Hexabrix-320(20%,30%,40%和50%)和Ca(10,20,30和40mgi / mL)中孵育大鼠腰椎IVDS来测定最佳造影剂浓度。 CT成像在70kVP,114A和250ms积分时间,12M体素尺寸进行。使用两种试剂的累积孵育量为0.5,1,2,12,16,20和24h的累积增强的动力学。通过相同IVDS的串行扫描评估形态定量的协议。通过酶促消化IVDS,随后的CT成像和通过二甲基亚甲基蓝色测定法测定对糖胺聚糖(GAG)含量的衰减的相关性。选择四十百分之六十百分之六厘米/ ml Ca(4+)作为最佳浓度。 Hexabrix使IVD从周围组织的更大描绘,Ca(4+)具有周围软组织的最低摄取。孵育24小时的孵育率为> 99%两种药剂的平衡。在IVD体积的定量(ICC = 0.951,R = 0.997)和高度(ICC = 0.947,R = 0.991)中,观察到高水平的协议。两种试剂在CT衰减和GAG含量之间表现出强烈的线性相关性(Hexabrix:R = -0.940; Ca(4+):r = 0.887)。两种试剂通过对比度增强的CT实现IVD的生物化学和形态定量,并且是临床前表征的有效工具。 (c)2016骨科研究会。由Wiley期刊出版,Inc。J Orthop Res 35:1067-1075,2017。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号