Accuracy of EBRA‐cup measurements after reconstruction of severe acetabular defects at revision THR

机译:修复严重髋臼缺损后eBRA杯测量的准确性

获取原文
获取原文并翻译 | 示例
           

摘要

Abstract Radiostereometric analysis (RSA) is the most accurate method of measuring component migration using radiographs but is restricted to use in prospective studies. Ein‐Bild‐Roentgen‐analyze (EBRA)‐Cup can be used retrospectively, but its accuracy to measure component migration following revision is unknown. This study aimed to determine the accuracy of EBRA‐Cup measurements of uncemented acetabular component migration after revision total hip replacement (THR). The secondary aim was to compare the number of cases identified using EBRA‐Cup and RSA as having proximally migrated above and below 1?mm at 2 years postoperatively. EBRA‐Cup measurements were performed on plain antero‐posterior pelvic radiographs taken at the same time as RSA radiographs in a prospective cohort of 53 hips undergoing acetabular revision. At 2 years, the mean difference between the RSA and EBRA‐Cup measurements for 17 components used to treat pelvic discontinuity was 0.90?mm, significantly greater than the mean difference of 0.28?mm for 36 components without discontinuity ( P ?=?.0001). The mean difference between the RSA and EBRA‐Cup measurements at 2 years for hips that were reconstructed with an acetabular component alone, 0.28?mm, was significantly lower than hips that were reconstructed with an acetabular component in combination with an augment and/or cage, 0.74?mm ( P ?=?.0005). In conclusion, EBRA‐Cup can accurately measure migration of uncemented acetabular components used at revision THR. The presence of pelvic discontinuity, and addition of augments and cages, significantly influenced the accuracy of EBRA‐Cup measurements. EBRA‐Cup and RSA had good agreement on classification of components that migrated proximally above or below 1?mm at 2 years, with 100% sensitivity, and 87% specificity.
机译:摘要辐射静脉分析(RSA)是使用射线照相测量组分迁移的最准确的方法,但仅限于前瞻性研究。 EIN-BILD-ROENTGEN-ANALYZE(EBRA)-CUP可以回顾性地使用,但其准确性来测量修订后的组件迁移是未知的。该研究旨在确定修订总髋关节置换(THR)后未致髋臼成分迁移的EBRA杯测量的准确性。二次目的是比较使用eBRA杯和RSA鉴定的病例数,因为在术后2年内在高于和低于1毫米的情况下近乎迁移。在普通的前后骨盆射线照片上进行EBRA杯测量作为RSA射线照相,其在经历髋臼修订的53个臀部的前瞻性队列中的RSA射线照片。在2年时,用于治疗盆腔不连续的17个组分的RSA和eBRA杯测量的平均差异为0.90Ωmm,显着大于36个组分的平均差异而没有不连续(P?= 0001 )。单独用髋臼组分重建的臀部的RSA和eBRA杯测量的平均差异为0.28Ωmm,与髋关节组分与增强和/或笼相结合重建的臀部显着低,0.74?mm(p?= 0005)。总之,EBRA-CUP可以准确地测量修订图中使用的未发布的髋臼部件的迁移。盆腔不连续性的存在,并增加增强和笼,显着影响了EBRA杯测量的准确性。 EBRA-CUP和RSA关于在2年后近乎或低于1?mm近乎迁移的组分的分类良好的一致性,具有100%的灵敏度和87%的特异性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号