首页> 外文期刊>Journal of orthopaedic research >Reliability of Quantitative Assessment of Distal Radioulnar Joint Stability With Force‐Monitor Ultrasonography
【24h】

Reliability of Quantitative Assessment of Distal Radioulnar Joint Stability With Force‐Monitor Ultrasonography

机译:具有力监测超声检查远端Radioulnar联合稳定性定量评估的可靠性

获取原文
获取原文并翻译 | 示例
           

摘要

ABSTRACT The purpose of this study was to evaluate the reliability of ultrasound assessment of the displacementforce relationships for distal radioulnar joint (DRUJ) stability. Nondominant wrists of 10 healthy male subjects were evaluated by forcemonitor ultrasonography. This apparatus was developed to apply cyclic compression to the wrist with predetermined transducer displacement conditions in the range of 0.13.0 mm. The subject's wrist was placed on the table with the forearm in the pronated position. The transducer was placed on the dorsal surface of the distal radius and ulna, perpendicular to the long axis of the forearm. The center of the ulnar head was at the DRUJ level. The distance between the dorsal surface of the distal radius and the ulnar head was measured at an initial and a presseddown position. Changes in radioulnar displacement, force to the wrist and the displacement/force ratio were evaluated. The measurements were performed independently by two raters. The intraclass correlation coefficients (ICCs) for the radioulnar displacement were 0.76, 0.68, and 0.93, in the 1.0, 2.0, and 3.0 mm transducer displacement conditions, respectively. The ICCs for the force to the wrist were 0.18, 0.67, and 0.34, in different transducer displacement conditions, respectively. The ICCs for the displacement/force ratios were 0.68, 0.67, and 0.97, in different transducer displacement conditions, respectively. The highest ICC for the radioulnar displacement and the displacement/force ratio was observed in the 3.0 mm displacement condition. This assessment of displacementforce relationships may be useful to quantify DRUJ stability. ?2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 37:20532060, 2019
机译:摘要本研究的目的是评估远端Radioulnar关节(DRUJ)稳定性的超声评估的可靠性。 10个健康男性受试者的Nondominant手腕由灭菌剂超声评估。开发该装置以将循环压缩施加到手腕上,具有预定的换能器位移条件,在0.13.0mm的范围内。将受试者的手腕用前臂放置在桌子上,在2位位置。将换能器置于远端半径和尺骨的背面上,垂直于前臂的长轴。尺骨的中心是Druj级别。在初始和压制位置测量远端半径的背面和尺骨头之间的距离。评估了Radioulnar位移的变化,对手腕的力和位移/力比进行了评估。测量以两个评估者独立进行。辐射流离失所的腹部相关系数(ICC)分别为0.76,0.68和0.93,分别为1.0,2.0和3.0mm换能器位移条件。在不同的换能器位移条件下,对手腕的力为0.18,0.67和0.34的ICCs。位移/力比的ICC分别分别为0.68,0.67和0.97,分别在不同的换能器位移条件下。在3.0mm位移条件下观察到Radioulnar位移的最高ICC和位移/力比。这种对位移的关系的评估可能有助于量化DRUJ稳定性。 ?2019年骨科研究会。由Wiley Hearyicals,Inc.J orthop Res 37:20532060,2019出版

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号