Treatment of Recurrent Intracranial Aneurysms: Gore-Tex Interposition Method for Prevention of Galvanic Corrosion at the Clips

机译:经复制颅内动脉瘤的治疗:GORE-TEX插入方法,用于防止夹子的电抗腐蚀

获取原文
获取原文并翻译 | 示例
           

摘要

We describe a new method for preventing galvanic corrosion induced by contact between old and new clips of different materials during clipping for recurrent intracranial aneurysms. After applying a new clip to the aneurysm neck close to the old clip, a Gore-Tex (GORE PRECLUDE; W.L. Gore & Associates, Inc., Newark, Delaware, United States) sheet is interposed to prevent contact between the old and new clip. The procedure was used successfully in three cases. The present technique is beneficial for the treatment of recurrent intracranial aneurysms to prevent galvanic corrosion when encountering difficulty in removing a previously placed clip.
机译:我们描述了一种预防在经常性颅内动脉瘤的夹子期间不同材料的旧和新夹子之间接触引起的电抗腐蚀的新方法。 在靠近旧剪辑的动脉瘤颈部将新夹子涂抹在戈尔-TEX(戈尔排除; WL Gore&Associates,Inc.,Newark,Delaware,美国)表中被插入,以防止旧和新剪辑之间的接触 。 该过程在三种情况下成功使用。 本技术有利于治疗复发性颅内动脉瘤,以防止在遇到难以去除先前放置的夹子时遇到电致腐蚀。