Intra-amniotic infection (IAI) is a common cause of pre-term labour. Manual WBC count on amniotic fluid (AF) has been suggested as a diagnostic test for IAI using a threshold of 50 cells/mm. However, no validation studies assessing the accuracy of this method have been performed. AF samples were selected for cell count analysis. WBCs were introduced to 47 AF samples. The results from two technologists' counts were compared with the calculated expected value for WBCs in these samples. Results showed that a comparison between the technologists' WBC count to the expected WBC count yielded R coefficients of 0.62 and 0.78, indicating moderate accuracy. Percentage agreement between the technologists was 67%, indicating low reproducibility. It was concluded that there was moderate correlation between the manual and the expected WBC in the spiked AF samples. Clinicians should be aware of the inaccuracy and imprecision associated with this test when evaluating a patient for IAI.
机译:羊皮内感染(IAI)是预期劳动力的常见原因。 手动WBC计数刚性液体(AF)的计数是使用50细胞/ mm的阈值的IAI对IAI的诊断测试。 然而,已经进行了评估该方法的准确性的验证研究。 选择AF样品进行细胞计数分析。 WBCS被引入47个AF样品。 将两位技术人员计数的结果与这些样品中的WBC的计算预期值进行了比较。 结果表明,技术人员WBC计数与预期的WBC计数之间的比较产生了0.62和0.78的R系数,表明中等精度。 技术人员之间的百分比协议为67%,表明再现低。 结论是手册与尖刺的AF样品中的预期WBC之间存在中等相关性。 当评估IAI时,临床医生应该了解与此测试相关的不准确性和不精确。