首页> 外文期刊>Journal of nanoparticle research: An interdisciplinary forum for nanoscale science and technology >An intercomparison exercise of good laboratory practices for nano-aerosol size measurements by mobility spectrometers
【24h】

An intercomparison exercise of good laboratory practices for nano-aerosol size measurements by mobility spectrometers

机译:迁移光谱仪对纳米气溶胶尺寸测量的良好实验室实践的相互熟练运动

获取原文
获取原文并翻译 | 示例

摘要

An intercomparison campaign on nanoparticle size measurement was organized in the frame of the French nanoMetrology club. The aim of this study is to make an inventory of the metrological capabilities of all measurement techniques in France involved in the "nano" size range, including the SMPS (scanning mobility particle sizer) concerning aerosol metrology. For this study, four samples have been proposed, namely (1) a SiO2 colloidal suspension (FD304) consisting of a monomodal population, (2) two samples consisting of two nanoparticle populations of SiO2 having proportions to be determined, and (3) a TiO2 colloidal suspension. Ten SMPS associated with five participants around a common experimental setup were performed in link with a control SMPS to have simultaneous measurements with a same instrument in each laboratory in parallel with the SMPS used by each partner. This article presents SMPS results of this study associated with the description of the experimental setup and the sample preparation protocol with an identified schedule and comparison with SEM measurements. The present paper does not focus on the actual capability of the tested mobility spectrometers, but aims to highlight the good laboratory practices using their own but common resources in terms of aerosol generation and measurement setups.
机译:在法国纳米术俱乐部的框架中组织了纳米粒子尺寸测量的相互熟练运动。本研究的目的是对法国的所有测量技术的计量能力进行库存,参与了“纳米”尺寸范围,包括关于气溶胶计量的SMPS(扫描迁移率粒子Sizer)。对于该研究,已经提出了四种样品,即(1)由单峰群(2)由单态常数(2)由具有比例的三种纳米粒子群组成的SiO 2胶体悬浮液(FD304)组成的两个样品,并且(3)a TiO2胶体悬浮液。在与控制SMP的链接中进行了10个与共同实验设置周围的参与者相关联的SMP,以在每个实验室中与每个伴侣使用的SMPS同时进行同时测量。本文介绍了该研究的SMPS结果与实验装置和样品制备方案的描述相关,具有鉴定的时间表和SEM测量比较。本文不关注测试的移动光谱仪的实际能力,但旨在突出良好的实验室实践在气溶胶生成和测量设置方面使用自己但共同的资源。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号