A fractal analysis is used to model the binding and dissociation kinetics of connective tissue interstitial glucose,adipose tissue interstitial glucose,insulin,and other related analytes on biosensor surfaces.The analysis provides insights into diffusion-limited analyte-receptor reactions occurring on heterogeneous biosensor surfaces.Numerical values obtained for the binding and the dissociation rate coefficients are linked to the degree of heterogeneity or roughness (fractal dimension,D_f)present on the biosensor chip surface.The binding and dissociation rate coefficients are sensitive to the degree of heterogeneity on the surface.For example,for the binding of plasma insulin,as the fractal dimension value increases by a factor of 2.47 from D_(f1)equal to 0.6827 to D_(f2)equal to 1.6852,the binding rate coefficient increases by a factor of 4.92 from k_1 equal to 1.0232 to k_2equal to 5.0388.An increase in the degree of heterogeneity on the probe surface leads to an increase in the binding rate coefficient.A dual-fractal analysis is required to fit the binding kinetics in most of the cases presented.A single fractal analysis is adequate to describe the dissociation kinetics.Affinity (ratio of the binding to the dissociation rate coefficient)values are also presented.Interferents for glucose such as uric acid and ascorbic acid were also detected using glucose biosensors based on carbon nanotube (CNT)nanoelectrode ensembles (NEEs)(29)(Lin,Y.;Lu,F.;Tu,Y.;Ren,Z.Nano Lett.2004,4 (2),191-195).Attempts are made to standardize biosensor properties in terms of diffusion characteristics on in vivo responsiveness.
机译:分形分析可用于模拟生物传感器表面上结缔组织间质葡萄糖,脂肪组织间质葡萄糖,胰岛素和其他相关分析物的结合和解离动力学。该分析提供了对异质生物传感器表面上发生的扩散受限的分析物-受体反应的见解。结合和解离速率系数的数值与存在于生物传感器芯片表面的异质性或粗糙度(分数维,D_f)有关。结合和解离速率系数对表面的异质性敏感例如,对于血浆胰岛素的结合,随着分形维数从D_(f1)等于0.6827到D_(f2)等于1.6852的因子增加了2.47倍,结合速率系数从k_1等于1.0232到k_2等于5.0388。探针表面异质性程度的增加会导致bin的增加在大多数情况下,需要进行双分形分析以适应结合动力学;单分形分析足以描述解离动力学;亲和力(结合度与解离速率系数的比)也应为还使用基于碳纳米管(CNT)纳米电极组件(NEEs)的葡萄糖生物传感器检测了葡萄糖的干扰素,例如尿酸和抗坏血酸(29)(Lin,Y。; Lu,F。; Tu,Y。; Ren) ,Z.Nano Lett.2004,4(2),191-195)。尝试根据扩散特性对体内响应性标准化生物传感器特性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号