During operative procedures, operating room personnel wear sterile surgical gloves designed to protect them and their patients against transmissible infections. The Food and Drug Administration (FDA) has set compliance policy guides for manufacturers of gloves. The FDA allows surgeons' gloves whose leakage defect rates do not exceed 1.5 acceptable quality level (AQL) to be used in operating rooms. The implications of this policy are potentially enormous to operating room personnel and patients. This unacceptable risk to the personnel and patient could be significantly reduced by the use of sterile double surgical gloves. Because double-gloves are also susceptible to needle puncture, a double-glove hole indication system is urgently needed to immediately detect surgical needle glove punctures. This warning would allow surgeons to remove the double-gloves, wash their hands, and then don a sterile set of double-gloves with an indication system. During the last decade, Regent Medical has devised non-latex and latex double-glove hole puncture indication systems. The purpose of this comprehensive study is to detect the accuracy of the non-latex and latex double-glove hole puncture indication systems using five commonly used sterile surgical needles: the taper point surgical needle, tapercut surgical needle, reverse cutting edge surgical needle, taper cardio point surgical needle, and spatula surgical needle. After subjecting both the non-latex and latex double-glove hole puncture indication systems to surgical needle puncture in each glove fingertip, these double-glove systems were immersed in a sterile basin of saline, after which the double-gloved hands manipulated surgical instruments. Within two minutes, both the non-latex and latex hole puncture indication systems accurately detected needle punctures in all of the surgical gloves, regardless of the dimensions of the surgical needles. In addition, the size of the color change visualized through the translucent outer glove did not correlate with needle diameter. On the basis of this extensive experimental evaluation, both the non-latex and latex double-glove hole puncture indication systems should be used in all operative procedures by all operating room personnel.
机译:在手术程序期间,手术室人员穿着无菌手术手套,旨在保护它们及其患者免受传染性感染。食品和药物管理局(FDA)为手套制造商设定了合规性政策指南。 FDA允许外科医生泄漏缺陷率不超过1.5的可接受质量水平(AQL)以便在手术室中使用。本政策的影响可能是手术室人员和患者的潜在巨大。通过使用无菌双手术手套,可以显着减少对人员和患者的这种不可接受的风险。由于双手套也容易受到针刺穿孔,因此迫切需要双手套孔指示系统,以便立即检测手术针手套穿孔。此警告将允许外科医生卸下双手套,洗手,然后用指示系统套一套无菌双手套。在过去十年中,摄政用医学设计了非乳胶和乳胶双手套孔穿刺指示系统。这种综合研究的目的是检测非乳胶和乳胶双手套孔穿刺指示系统的准确性,使用五种常用的无菌手术针:锥度外科手术针,圆锥形手术针,反向切削刃外科针,锥度心脏点外科针和刮刀外科手术针。在将非胶乳和乳胶双手套孔穿刺指示系统进行手术针刺后,将这些双手套系统浸入盐水中的无菌盆地,之后是双手套的手操纵手术器械。在两分钟内,无论手术针的尺寸如何,都会在两分钟内精确地检测到所有手术手套中的针刺刺穿。另外,通过半透明外套的颜色变化的尺寸与半径不相关。在这一广泛的实验评估的基础上,所有手术室人员都应用于所有手术程序的非乳胶和乳胶双手套孔穿刺指示系统。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号