PERFORMANCE EVALUATION OF DRY EYE DETECTION SYSTEM USING HIGHER-ORDER SPECTRA FEATURES FOR DIFFERENT NOISE LEVELS IN IR THERMAL IMAGES

机译:使用高阶光谱特征在IR热图像中使用高阶光谱特征的干眼检测系统性能评估

获取原文
获取原文并翻译 | 示例

摘要

The enhanced tear film evaporation and diminished tear production causes a dry eye (DE) condition. A non-invasive infrared (IR) thermography is most commonly used as a diagnostic tool for diagnosis of DE. However, the availability of high-quality IR thermal camera at low cost is difficult. Hence, an efficient DE detection system which can perform efficiently by using low-cost and low-quality images instead of conventional IR images would be a significant contribution. Therefore, in this work, we have evaluated the performance of automated noninvasive DE detection system using low-quality images obtained by adding different levels of noise to high-quality IR images. In this work, the performances of two non-linear higher-order spectra (HOS) cumulants and bispectrum features are compared. These features are extracted from the IR images with different levels of Gaussian noise. Principal component analysis (PCA) is performed on these extracted features and they are ranked using t-value and later fed to different classifiers. We have achieved the accuracies, sensitivities and specificities of: (i) 86.90%, 85.71% and 88.10%, with noise level 0 using 24 bispectrum features, and (ii) 80.95%, 85.71% and 76.19%, with noise level 10 using 15 bispectrum features for right eye IR images. This study exhibits that even in the presence of high levels of noise, the detection of DE is possible and our proposed method performs efficiently using HOS bispectrum features. Thus, our proposed method can be used to detect DE using low-quality and inexpensive cameras instead of high-cost IR camera.
机译:增强的泪膜蒸发和撕裂产量减少导致干眼症(DE)条件。无侵入式红外线(IR)热成像最常用作诊断DE的诊断工具。然而,难以低成本的高质量IR热摄像机的可用性。因此,可以通过使用低成本和低质量的图像而不是传统的IR图像有效地执行的有效的DE检测系统将是一个显着的贡献。因此,在这项工作中,我们已经评估了使用通过将不同水平的噪声添加到高质量的IR图像而获得的低质量图像来评估自动非侵入性DE检测系统的性能。在这项工作中,比较了两种非线性高阶谱(HOS)累积剂和BISPectrum特征的性能。这些特征是从IR图像中提取,具有不同级别的高斯噪声。主成分分析(PCA)对这些提取的特征进行,并且它们使用T值排序,后来馈送到不同的分类器。我们已经达到了:(i)86.90%,85.71%和88.10%的准确性,敏感性和特异性,噪声水平0使用24 bispectrum特征,(ii)80.95%,85.71%和76.19%,具有噪声水平10使用15个BISPectrum特性右眼红外图像。本研究表现出即使在高水平的噪声存在下,可以使用HOS BISPectrum特征的方法和我们所提出的方法进行有效的检测。因此,我们所提出的方法可用于检测使用低质量和廉价的摄像机而不是高成本的IR相机。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号