A portable electrophoresis device based on the SU-8/Pyrex microfluidic chip with integrated three 100 m platinum (Pt) thin-film electrodes (working, reference, and auxiliary) was adapted for the analysis of silver nanoparticles (AgNPs). The microfluidic platform includes the main electrophoresis instrument, reusable holder, and microfluidic chip with integrated Pt electrodes. The electrochemical oxidation behaviours of AgNPs on Pt thin-film electrode were investigated by using cyclic voltammetry, while the electrophoresis behaviours of AgNPs were studied on the Lab-on-a-chip' platform. The influences of parameters including running buffer, separation voltage, and detection potential on the electrophoresis behaviours of AgNPs were all investigated. The results showed that AgNPs could be oxidised at 0.2-0.4 V [phosphate buffer solution buffer, pH 7.0] on the Pt thin-film electrode. The peak current enhanced with the increase of separation voltage, while the retention time decreased. The peak current varied with the detection potential and reached the highest value at 0.4 V. This microfluidic platform could be a fast and portable detection system for the analysis of total AgNPs.
机译:一种基于SU-8 / Pyrex微流体芯片的便携式电泳装置,具有集成的三种100m铂(Pt)薄膜电极(加工,参考和辅助),适用于银纳米粒子(AgNP)的分析。微流体平台包括主电泳器械,可重复使用的支架和具有集成Pt电极的微流体芯片。使用循环伏安法研究了Pt薄膜电极上AgNP的电化学氧化行为,而在芯片的平台上研究了AgNP的电泳行为。全部研究了包括运行缓冲液,分离电压,分离电压和检测电位的参数的影响。结果表明,AgNP可以在PT薄膜电极上以0.2-0.4V [磷酸缓冲液缓冲液,pH7.0]氧化。峰值电流随着分离电压的增加而增强,而保留时间降低。峰值电流随检测电位而变化,并达到0.4V的最高值。该微流体平台可以是用于分析总AgNP的快速和便携式检测系统。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号