首页> 外文期刊>Journal of hand therapy: Official journal of the American Society of Hand Therapists >Shoulder proprioception: How is it measured and is it reliable? A systematic review
【24h】

Shoulder proprioception: How is it measured and is it reliable? A systematic review

机译:肩膀预言:它如何测量,它是可靠的吗? 系统评价

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Abstract Study Design Systematic review. Introduction Constituents of proprioception include our awareness of the position (joint position sense [JPS]) and motion (kinesthesia) of our limbs in space. Proprioceptive deficits are associated with musculoskeletal disorders but remain a challenge to quantify, particularly at the shoulder. Purpose of the Study To report the psychometric values of validity, reliability, and responsiveness for shoulder JPS and/or kinesthesia protocols. Methods A review of 5 databases was conducted from inception to July 2016 for studies reporting a psychometric property of a shoulder proprioception protocol. The included studies were evaluated using the QualSyst checklist and COSMIN 4-point scale. Results Twenty-one studies were included, yielding 407 participants and 553 evaluated shoulders (n). The included studies support excellent methodological scores using the QualSyst checklist (88.1 ± 9.9%) and good psychometric scores with the COSMIN for reliability (71.1%) and moderate-to-low quality score (50%) for criterion validity. Weighted average intraclass correlation coefficients (ICCs) for intrarater reliability were highest for passive JPS and kinesthesia, ICC = 0.92 ± 0.07 ( n = 214) and ICC = 0.92 ± 0.04 ( n = 74), respectively. The most reliable movement and tool are internal rotation at 90° of abduction, ICC = 0.88 ± 0.01 ( n = 53), and the dynamometer, ICC = 0.92 ± 0.88 ( n = 225). Only 2 studies quantify an aspect of validity and no responsiveness indices were reported among the included studies. Conclusion Based on the results of the included studies, the evaluation of shoulder proprioception is most reliable when using a passive protocol with an isokinetic dynamometer for internal rotation at 90° of shoulder abduction. Standardized protocols addressing the psychometric properties of shoulder proprioception measures are needed. Level of Evidence Level 1a: systematic review.
机译:抽象研究设计系统评价。预言的引言组成部分包括我们对太空中四肢的位置(关节位置感测[JPS])和运动(Kinesthesia)的认识。 Brobrioceptivity缺陷与肌肉骨骼疾病有关,但仍然是量化的挑战,特别是在肩部。该研究的目的是报告肩部JPS和/或Kinesthesia协议的有效性,可靠性和响应性的心理测量值。方法审查5次数据库的审查是从2016年7月的成立进行报告,报告肩部预防议定书的心理学。使用Qualsyst清单和Cosmin 4点刻度评估所纳入的研究。结果包括二十一项研究,产生407名参与者和553名评估肩部(N)。包括的研究支持使用Qualsyst核对表(88.1±9.9%)和康复的良好的心理测量分数以及用于可靠性(71.1%)和中等至低质量分数(50%)的良好的心理学分数,以获得标准有效性。对于无源JPS和Kinesthesia,ICC = 0.92±0.07(n = 214)和ICC = 0.92±0.04(n = 74),ICC = 0.92±0.07(n = 74),ICC = 0.92±0.04(n = 74)的加权平均腹部相关系数(ICCs)最高。最可靠的运动和工具是在90°展出的内部旋转,ICC = 0.88±0.01(n = 53),测功机,ICC = 0.92±0.88(n = 225)。只有2项研究量化了有效性的一个方面,并且在内的研究中没有报告响应指数。结论基于所介绍的研究结果,当使用具有等幂测功机的无源方案时,肩部预防的评估是最可靠的。需要解决肩部预防措施的心理测量性能的标准化协议。证据级别1A:系统审查。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号