The paper presents a case of an atypical iatrogenic complication after tracheotomy analyzed on the basis of the case dossier materials submitted to the authors by the court of justice to prepare a forensic medical opinion concerning the correctness of the medical procedure. A 37-year-old woman was brought by the ambulance service to the hospital with acute respiratory failure due to post-tracheostomy tracheal stenosis. Tracheotomy was performed on an emergency basis. The patient suffered severe burns of the chest and neck. The experts concluded that the most probable cause of the incident was electrocautery-induced ignition of the disinfectant used for cleaning the skin before the surgery. It was established that with correct handling of the procedure, the aforementioned incident should not have taken place. Therefore, it cannot be regarded as a normal complication inherent in the risk associated with the procedure, but as a consequence of a medical error.
机译:本文提出了在法院向提交人提交给作者的情况下分析的气管切开术后的非典型性成原体并发症的情况,以制定关于医疗程序的正确性的法医医学意见。 由于气管造口术后气管狭窄,救护车服务将救护车服务带来了一名37岁的女性。 气管切开术在紧急情况下进行。 患者患胸部和颈部的严重灼伤。 专家得出结论,该事件最可能的原因是电陶器诱导的消毒剂点火,用于清洁手术前的皮肤。 正建立,通过正确处理程序,不应发生上述事件。 因此,它不能被视为与程序相关的风险中固有的正常并发症,而是由于医疗错误的结果。