首页> 外文期刊>Journal of esthetic and restorative dentistry: official publication of the American Academy of Esthetic Dentistry ... [et al.] >Evaluation of the trueness and precision of complete arch digital impressions on a human maxilla using seven different intraoral digital impression systems and a laboratory scanner
【24h】

Evaluation of the trueness and precision of complete arch digital impressions on a human maxilla using seven different intraoral digital impression systems and a laboratory scanner

机译:利用七种不同的血管内数字印象系统和实验室扫描仪评估人类颌骨完整拱形数字印象的真实和精度

获取原文
获取原文并翻译 | 示例
       

摘要

Abstract Objectives An impression accuracy study using a cadaver maxilla was performed using both prepared and intact teeth as well as palatal tissue. Materials and Methods Three crown preparations were performed on a cadaver maxilla. Seven different digital impression systems along with polyvinylsiloxane impressions were used to create digital models of the maxilla. Three‐dimensional (3D) files of the experimental models were compared to a master model. The 3D files were overlaid and analyzed using a comparison software to create color coded figures that were measured for deviations between the master and experimental models. Results For scanning tooth structure, only the Planscan was significantly less accurate than the rest of impression techniques. No significant differences in accuracy were found between models created using digital impressions and those created from traditional vinyl polysiloxane impressions with cross arch deviations ranging from 18 to 39 μm for each. Conclusions Impressions taken using all digital impression systems, save for the Planscan, were able to accurately replicate the tissues of a complete arch human maxilla. Clinical Significance Studies examining accuracy of digital impression systems have generally been performed on materials other than dental tissues. Optically, materials such as plastic and metal have properties different from enamel and dentin. This study evaluates accuracy of digital impression systems on human dentin, enamel, and soft tissues.
机译:摘要目的使用使用尸体颌面颌面颌面颌面颌面颌面表的印象精度研究。材料和方法在尸体上颌骨上进行三个冠状制剂。七种不同的数字印象系统以及聚乙烯基硅氧烷印象用来造成颌骨的数字模型。将实验模型的三维(3D)文件与主模型进行比较。使用比较软件重叠并分析3D文件以创建用于偏差的彩色编码图,以便在主设备和实验模型之间进行偏差。扫描牙齿结构的结果,只有计划才能明显低于其余印模技术的准确性。在使用数字印象创建的模型之间没有显着差异,以及由传统的乙烯基聚硅氧烷印象产生的模型之间,每个交叉弓偏差为每次18至39μm。结论使用所有数字印象系统采取的印象,保存为计划,能够准确地复制完整拱形人体上颌的组织。临床意义研究似乎对牙科组织以外的材料进行了数字印模系统的准确性。光学上,诸如塑料和金属等材料具有与珐琅和牙本质不同的性质。本研究评估了人类牙本质,牙釉质和软组织上的数字印象系统的准确性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号