首页> 外文期刊>Journal of Failure Analysis and Prevention >Corrosion Failure Analysis on Heat Exchanger Pipes
【24h】

Corrosion Failure Analysis on Heat Exchanger Pipes

机译:换热器管道腐蚀失效分析

获取原文
获取原文并翻译 | 示例
           

摘要

The heat exchange pipes in one synthetic ammonia plant were in use for only thirteen months, but obvious leakage occurred in the pipes. Investigations indicated that corrosion of the pipes was quite serious, resulting in corrosion pits penetrating the pipes in some spots. Analysis on the metallurgical structure indicated that no problems existed on the pipe material AISI 1020 low carbon steel; the corrosion inhibitors or scale inhibitors were added in the circulating water. The only problem was deduced to exist in the maintenance of the pipes during the idling period; survey of the maintenance of the pipes during the idling period proved the deduction above. Since no effective measures were taken to protect the pipes in the coolers and the circulating water was not emptied, the corrosion products and scales deposited on the pipes and formed local occluded cells; the occluded cells accelerated the pitting corrosion of the pipes and induced leakage in a short time.
机译:一种合成氨植物中的热交换管仅用于13个月,但在管道中发生明显的泄漏。 调查表明,管道的腐蚀相当严重,导致腐蚀坑在一些斑点中穿透管道。 冶金结构的分析表明,在管材AISI 1020低碳钢上没有任何问题。 在循环水中加入腐蚀抑制剂或水垢抑制剂。 在怠速期间,唯一的问题被推导出存在于管道的维护中; 怠速期间管道维护调查证明了上述扣除。 由于没有采取有效措施来保护冷却器中的管道,并且没有清空循环水,腐蚀产品和沉积在管子上的鳞片和形成的局部闭塞细胞; 闭塞细胞加速了管道的蚀腐蚀,并在短时间内引起泄漏。