This study involves the failure analysis of carbon steel tubes in a reformed gas boiler feed water preheater unit operating at an ammonia plant. It was determined that the incipient failure mechanism in the carbon steel tubes was pitting corrosion at the inner surface of the failed tube transporting boiler feed water. The spectroscopic and microscopic analysis revealed the presence of iron oxides, including magnetite (Fe_3O_4), on the surface of a hole inside a pit formed in the inner surface. A significant thickness reduction in the internal wall due to subsequent erosion-corrosion led to the formation of the hole. No voids/cracks were present in the grain boundaries in the (ferritic and pearlitic) microstructure of the carbon steel tube (A214). Due to the recurrent nature of the failure of the carbon steel tubes in the preheater unit, SS304L tubes are recommended to be used throughout the waterside of the preheater.
机译:本研究涉及在氨植物操作的重整燃气锅炉饲料水预热器单元中碳钢管的故障分析。 确定碳钢管中的初始故障机制在失效的管道输送水的内表面处蚀刻腐蚀。 光谱和微观分析显示,在形成在内表面的凹坑内的孔的表面上存在氧化铁的存在,包括磁铁矿(Fe_3O_4)。 由于随后的腐蚀腐蚀导致孔的形成,内壁的显着厚度减小。 在碳钢管(A214)的(铁素体和珠光体)微结构中没有空隙/裂缝存在于晶界中(A214)。 由于预热器单元中的碳钢管失败的复发性,建议使用SS304L管在整个浇水器的整个水域中使用。