...
首页> 外文期刊>Journal of Endodontics: Official Journal of American Association of Endodontists >Apical Transportation, Centering Ratio, and Volume Increase after Manual, Rotary, and Reciprocating Instrumentation in Curved Root Canals: Analysis by Micro-computed Tomographic and Digital Subtraction Radiography
【24h】

Apical Transportation, Centering Ratio, and Volume Increase after Manual, Rotary, and Reciprocating Instrumentation in Curved Root Canals: Analysis by Micro-computed Tomographic and Digital Subtraction Radiography

机译:手动,旋转和往复式仪表中的顶端运输,定心比和体积增加,弯曲根部运河:通过微计算机断层摄影和数字减法射线照相分析

获取原文
获取原文并翻译 | 示例
           

摘要

Introduction: This study aimed to evaluate apical transportation (AT), centering ratio (CR), and volume increase (VI) produced after instrumentation of mesiobuccal canals of maxillary molars with hand files, rotary, and reciprocating instruments using micro computed tomographic (micro-CT) imaging and to demonstrate the ability of digital subtraction radiography (DSR) to evaluate AT. Methods: Forty-five canals were randomly assigned to either group K, manual K -files; PTN, ProTaper Next (Dentsply Maillefer, Ballaigues, Switzerland); or Rec, Reciproc (n = 15 for each group) for preparation. Master apical files were #25, X2 (#25/06), and R25 (#25/08), respectively. Micro-CT imaging was used to measure AT (mm) and CR (mm) at 3 different locations (1, 4, and 7 mm from the apex). VI (mm3) was measured for each root third and for the whole canal. DSR (mesiodistal and buccolingual projections) was used to measure AT at 1 mm from the apex. Results: AT and CR values were statistically similar across the groups at 1, 4, and 7 mm. AT results obtained for the different locations were similar within each group; CR, in turn, showed statistically lower values at 1 mm. VI was statistically similar in all groups. Both DSR and micro-CT imaging showed that AT always occurred on the outside of canal curvature. The highest mean value obtained for AT was 0.215 mm. Conclusions: AT, CR, and VI were similar for the K, PTN, and Rec groups. AT results were clinically irrelevant. DSR was as effective as micro-CT imaging in AT analysis and could be considered as an alternative method for assessing this outcome.
机译:介绍:本研究旨在评估在使用微计算机,旋转和往复仪器的颌骨磨碎机仪器仪器中产生的顶端运输(AT),定性比(CR),和体积增加(VI),使用微型计算机断层形成(微 - CT)成像并展示数字减法放射线照相(DSR)评估的能力。方法:将四十五个运河随机分配给K,手动K -Files组; PTN,Propaper Next(Lentsply Maillefer,Ballaigues,Switzerland);或者,反转(每组n = 15)以制备。主顶端文件分别为#25,x2(#25/06)和R25(#25/08)。微型CT成像用于在3个不同位置(1,4和7mm)的(毫米)和Cr(mm)处测量(1,4和7mm)。为每个根部第三和整个运河测量VI(mm3)。 DSR(中生和Buccolingual突出线)用于距离顶点的1mm处。结果:AT和Cr值在1,4和7毫米的组上统计学相似。在每个组内获得不同位置的结果;反过来,CR在1毫米的统计上较低。 VI在所有群体中都在统计上类似。 DSR和Micro-CT成像均显示出在运河曲率的外部始终发生。获得的最高平均值为0.215mm。结论:AT,CR和VI类似于K,PTN和REC组。结果是临床无关紧要的。 DSR在分析中作为微型CT成像如微型CT成像,并且可以被认为是评估这一结果的替代方法。

著录项

相似文献

  • 外文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号