首页> 外文期刊>Journal of chromatography, B. Analytical technologies in the biomedical and life sciences >Development of a hematocrit-insensitive device to collect accurate volumes of dried blood spots without specialized skills for measuring clozapine and its metabolites as model analytes
【24h】

Development of a hematocrit-insensitive device to collect accurate volumes of dried blood spots without specialized skills for measuring clozapine and its metabolites as model analytes

机译:开发血细胞比容不敏感器件,收集精确的干血斑,而无需测量氯氮平及其代谢物作为模型分析物的专业技能

获取原文
获取原文并翻译 | 示例
           

摘要

Dried blood spots have been used as alternatives to traditional plasma and serum samples. We have now developed new devices, named volumetric absorptive paper disc (VAPD) and mini-disc (VAPDmini), to collect accurate volumes of dried blood spots in a simple manner and without the need for additional instruments. VAPD consists of a filter paper disc and a filter paper sheet with holes slightly larger than the disc. The disc is fixed in one such hole without direct contact with the filter sheet. VAPDmini is a scaled-down version of the same device. When several drops of whole blood are applied, the disc becomes saturated and any excess sample is absorbed by the surrounding filter sheet. Accuracy and precision of sampling were assessed by determining the levels of clozapine and its metabolites as target analytes by liquid-liquid extraction and high-performance liquid chromatography with coulometric detection. In addition, differences in analyte recovery were within +/- 15% for all analytes in samples with 30-60% hematocrit, suggesting that VAPD and VAPDmini are insensitive to hematocrit for the analytes tested. The devices were also validated for analyte concentrations in the range 50-1000 ng/mL, and the limit of detection and lower limit of quantification were 5-17 ng/mL and 15-51 ng/mL, respectively. Infra- and inter-day precision ranged from 3% to 13%, whereas accuracy ranged from a - 14% to 12% bias. Analytes were stable in the devices for at least 2 weeks at room temperature. Collectively, these results indicate that sampling using VAPD and VAPDmini is comparable to conventional hole punch sampling of entire dried blood spots, even for samples obtained from patients treated with clozapine. Importantly, the devices were also found to be suitable for sample self-collection.
机译:干血斑被用作传统血浆和血清样品的替代品。我们现在已经开发了新的设备,名为体积吸收纸盘(VAPD)和迷你盘(VAPDMINI),以简单的方式收集精确的干血液斑点,而无需其他仪器。 VAPD由滤纸盘和过滤纸张组成,滤纸,孔略大于盘。盘固定在一个这样的孔中,而不直接接触过滤片。 VAPDMINI是同一设备的缩放版本。当施加几滴全血时,盘变饱和,并且通过周围的过滤片吸收任何过量的样品。通过用液 - 液萃取和高性能液相色谱法测定氯氮平及其代谢物作为靶分析物,通过液 - 液提取和库仑检测来评估取样的准确性和精度。此外,分析物回收的差异在含有30-60%的血细胞比容的样品中的所有分析物中的+/- 15%,表明VAPD和VAPDMINI对测试的分析物的血细胞比容不敏感。还验证了该装置的分析物浓度,范围为50-1000ng / mL,检测极限和定量下限分别为5-17ng / ml和15-51ng / ml。当天和日内的精度范围为3%至13%,而精度范围从A-14%到12%偏差。分析物在室温下在装置中稳定至少2周。总的来说,这些结果表明使用VAPD和VAPDMINI的采样与整个干血斑的常规空穴冲击采样相当,甚至对于由氯氮平处理的患者获得的样品。重要的是,还发现该装置适用于样品自集。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号