Abstract Aim To clinically evaluate a type of patented automated anesthesia cart in medication administrations in anesthesia. Materials and Methods This was a prospectively randomized open label clinical trial. In 10 designated operating suits in the First Affiliated Hospital of Zhengzhou University, in China. 1066 cases originated from 10,812 medication administrations in anesthesia were randomized. 78 registered anesthesiologists managed the medication. The patients received medication administrations in anesthesia with either an automated or a conventional manual cart. American Society of Anesthesiologists (ASA) score, sex, duration of anesthesia and surgical specialty, errors in administration of medications (incorrect medication given (substitution), medication not given (omission) and drug recordings errors”), compliance and satisfaction were recorded. Results The total error rate was 7.3% with the automated anesthesia carts (1 in 14 administrations) and 11.9% with conventional manual carts (1 in 8 administrations). Automated anesthesia carts significantly reduced the drug recording error rate compared to conventional manual carts ( P 0.01). However, no significant difference of substitution or errors omission errors was found between groups of automated anesthesia carts and conventional manual carts. The anesthesiologists' compliance with the automated anesthesia carts was unsatisfactory, and all the errors in medication recordings with the automated anesthesia carts were due to the incorrect use of the carts. Most of the participating anesthesiologists preferred the automated anesthesia carts ( P 0.05). Conclusions The utilization of automated anesthesia carts reduced the drug recording errors in medication administrations of anesthesia. Highlights ? Automated anesthesia carts reduced the error rate; ? Anesthesiologists' compliance to the automated anesthesia carts was not satisfactory; ? Most of the participating anesthesiologists preferred the automated anesthesia carts.
机译:摘要旨在在麻醉中临床评估一种专利的自动麻醉购物车。材料和方法这是一个前瞻性随机的开放标签临床试验。在中国郑州大学第一家附属医院的10个指定的经营套装中,在中国。 1066例起源于10,812个麻醉药物随机化。 78名注册麻醉学家管理药物。患者在麻醉中接受了用自动化或传统手动推车的麻醉药物。美国麻醉学家(ASA)评分,性别,麻醉和外科手术特性,药物管理中的错误(给予不正确的药物(替代),未给药(遗漏)和药物记录错误“),合规性和满足感。结果总误差率为7.3%,自动麻醉推车(14个主管部门)和11.9%,常规手动推车(8人在8个主管部门)。与传统手动推车相比,自动麻醉推车显着降低了药物记录错误率(P <0.01)。然而,在自动麻醉推车组和传统手动推车之间没有发现替代或错误遗漏误差的显着差异。麻醉学家遵守自动麻醉推车是不令人满意的,并且使用自动麻醉推车的药物记录中的所有错误都是由于推车的使用不正确。大多数参与的麻醉药店首选自动麻醉推车(P <0.05)。结论自动麻醉推车的利用减少了麻醉药物药物中的药物记录误差。强调 ?自动麻醉推车降低了错误率;还麻醉师对自动麻醉推车的遵守性并不令人满意;还大多数参与的麻醉药店首选自动麻醉推车。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号