首页> 外文期刊>Journal of cataract and refractive surgery >Diagnostic capacity of the keratoconus match index and keratoconus match probability in subclinical keratoconus
【24h】

Diagnostic capacity of the keratoconus match index and keratoconus match probability in subclinical keratoconus

机译:角蛋白酶匹配指数和角蛋白酶匹配概率在课程角蛋白的诊断能力

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose To evaluate the diagnostic capacity of the Ocular Response Analyzer's keratoconus match index (KMI) and keratoconus match probability (KMP) classification in keratoconus-suspect eyes. Setting Department of Ophthalmology, University Clinics Saarland, Homburg, Germany. Design Comparative case series. Methods The KMI and KMP parameters in keratoconus-suspect eyes and normal eyes (control group) were compared. The quantitative keratoconus percentage index was calculated for all suspect eyes. According to the thinnest corneal thickness (TCT), keratoconus-suspect eyes were divided into 2 subgroups: subgroup 1 (TCT <520 μm) and subgroup 2 (TCT >520 μm). The KMI's overall predictive accuracy was assessed using receiver operating characteristic (ROC) curves. The relationship between KMI and a series of Scheimpflug-derived keratoconus-related indices was evaluated using Spearman analysis. Results The mean KMI was 0.41 ± 0.29 (SD) in the keratoconus-suspect group (50 eyes) and 0.94 ± 0.29 in the control group (50 eyes) (P<.001). Nonsignificant KMI differences were detected between the keratoconus-suspect subgroups (subgroup 1, 27 eyes; subgroup 2, 23 eyes) (P=.059). Nonsignificant correlations were found between Scheimpflug indices and the KMI. The KMP identified 27.65% of control eyes as keratoconus suspect and 10.71%, 28.57%, and 3.57% of keratoconus-suspect eyes as being normal, having mild keratoconus, or having moderate keratoconus, respectively. The ROC analysis for the KMI indicated a predictive accuracy of 94% (cutoff point 0.72). Conclusions The KMI seems to be a valuable index in the early diagnosis of keratoconus-suspect eyes. The KMP identified a significant percentage of topographically defined keratoconus-suspect eyes as normal or keratoconic. Financial Disclosure No author has a financial or proprietary interest in any material or method mentioned.
机译:目的,评估眼睛响应分析仪的角蛋白匹配指数(KMI)和KeratoConus匹配概率(KMP)分类的诊断能力在KeratoConus-Sompect的眼睛中。制定眼科,大学诊所Saarland,德国普林斯省的部门。设计比较案例系列。方法比较了KeratoConus-Sompect眼睛和正常眼睛(对照组)中的KMI和KMP参数。针对所有可疑眼睛计算定量角蛋白酶百分比指数。根据最薄的角膜厚度(TCT),KeratoConus-Sompect眼睛分为2个子组:亚组1(TCT <520μm)和亚组2(TCT>520μm)。使用接收器操作特征(ROC)曲线评估KMI的总体预测精度。使用Spearman分析评估KMI与一系列Scheimpflum衍生的KeratoConus相关指数的关系。结果KeratoConus-Sompect组(50只眼)中的平均值MIMI为0.41±0.29(SD),对照组(50只眼)0.94±0.29(P <.001)。在角蛋白组可疑亚组(亚组1,27眼中;亚组2,23眼)之间检测不显着的KMI差异(P = .059)。 Scheimpflug指数和KMI之间发现了不显着的相关性。 KMP将27.65%的控制眼为角蛋白嫌疑人,10.71%,28.57%和3.57%的角蛋白嫌疑人的眼睛是正常的,具有轻度角蛋白,或具有中等的角蛋白酶。 KMI的ROC分析表明了94%的预测精度(截止点0.72)。结论KMI似乎是KeratoConus-Sompect眼睛的早期诊断的宝贵指标。 KMP确定了正常或角振难关的巨大地形定义的角质棉的显着百分比。财务披露没有提交人对提到的任何材料或方法都有财务或专有权益。

著录项

  • 来源
  • 作者单位

    Department of Ophthalmology University Medical Center of Saarland UKS Homburg/Saar Germany;

    Ophthalmology Department Eye Institute of Thrace University Hospital of Alexandroupolis 68100;

    Department of Ophthalmology University Medical Center of Saarland UKS Homburg/Saar Germany;

    Ophthalmology Department Eye Institute of Thrace University Hospital of Alexandroupolis 68100;

    Ophthalmology Department Eye Institute of Thrace University Hospital of Alexandroupolis 68100;

    Department of Ophthalmology University Medical Center of Saarland UKS Homburg/Saar Germany;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 眼科学;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号