首页> 外文期刊>Journal of clinical neuroscience: official journal of the Neurosurgical Society of Australasia >Measured volumes using segmented tissue probability data obtained using statistical parametric mapping 12 were not influenced by the contrasts of analyzed images
【24h】

Measured volumes using segmented tissue probability data obtained using statistical parametric mapping 12 were not influenced by the contrasts of analyzed images

机译:使用使用统计参数映射12获得的分段组织概率数据的测量体积不受分析图像的对比度的影响

获取原文
获取原文并翻译 | 示例
           

摘要

The aim of this study was to evaluate changes in measured volumes using Statistical Parametric Mapping (SPM) 12 caused by contrast changes in magnetic resonance (MR) image. Twenty-one healthy subjects participated in the study. From all subjects, 3D T1-weighted images (T1WIs) were obtained using a 3T scanner. In the first step of creating reference volume data, we used SPM12 to binarize all the segmented data. In the second step, we assigned simulated 3D-T1WI signal intensities to each tissue image and used the following values. The last step was integration of each tissue image to generate 3D-T1WI simulated reference volume data for each participant. To create the reference 3D-T1WIs with various contrasts from the reference volume data, we varied the signal intensity of gray matter from 900 to 600, 700, 1100, 1300, and 1400. The reference 3D-T2WI was acquired using the method used for 3D-T1WIs. Then, six 3D-T1WIs were processed using intrasubject bias-correction processing with SPM12, resulting in six new 3D-T1WIs of nonuniform signal intensities. Thirteen volume data sets were segmented into native-space tissue probability data using SPM12. Examination of the 3D data without nonuniform signal intensity showed that significant differences in measured volumes were not observed on repeated analysis of variance, but examination of the 3D data with nonuniform signal intensity did show significant differences in measured volumes in gray matter and CSF but not in white matter. Measured volumes using segmented tissue probability data obtained using SPM12 were not influenced by the contrasts of analyzed images. (C) 2020 Elsevier Ltd. All rights reserved.
机译:本研究的目的是使用统计参数映射(SPM)12评估测量体积的变化,由磁共振(MR)图像的对比度变化引起。二十一位健康受试者参加了这项研究。从所有受试者,使用3T扫描仪获得3D T1加权图像(T1WIS)。在创建参考卷数据的第一步中,我们使用SPM12将所有分段数据二值化。在第二步中,我们为每个组织图像分配了模拟的3D-T1WI信号强度并使用以下值。最后一步是集成每个组织图像,以为每个参与者生成3D-T1WI模拟参考体积数据。要从参考音量数据创建具有各种对比度的参考3D-T1WIS,我们将信号强度从900到600,700,1100,1300和1400变化。使用用于的方法获取参考3D-T2WI 3D-T1WIS。然后,使用具有SPM12的intrAsbject偏压校正处理处理六个3D-T1Wis,从而产生六个非均匀信号强度的六个新的3D-T1Wis。使用SPM12将十三卷数据集分段为天然空间组织概率数据。在没有非均匀信号强度的3D数据的检查表明,在反复分析方差分析时未观察到测量体积的显着差异,但是具有非均匀信号强度的3D数据的检查确实显示出灰质物质和CSF中的测量体积的显着差异,但不呈现白质。使用使用SPM12获得的分段组织概率数据的测量体积不受分析图像的对比度的影响。 (c)2020 elestvier有限公司保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号