Process safety of hazardous phosgenation reactions during industrial chemical production is a critical issue. We herein have designed a compact flow reaction process for phosgenation reactions and successfully installed the system at a commercial plant. The hold-up of phosgene was significantly reduced and a leakage detecting system was incorporated in the commercial process. A scale-up method for determining the mixing condition of the commercial-scale flow reactor was the most important task in this study. The Villermaux-Dushman reaction was employed to evaluate the mixing performance of the T-shaped mixers with the mixer outlet diameter, D_m ranging from 0.5 x 10~(-3) to 15.0 x 10~(-3) m. The scale-up condition was determined by the absorbance of the Villermaux-Dushman reaction solution. Utilizing the experimental results, a diagram of the mixing performance in terms of D_m and the flow rate was obtained. It was found that the fluid segment size W_c ( = D_m/2~(0.5)) in a T-shaped mixer, and the Reynolds number of the mixer flow Re are important parameters for mixing in the T-shaped mixers. We derived the correlation between the mixing performance and W_c/Re~n. It was found that all of the mixers utilized in this study had the same correlation with an n value of 1.19. We also confirmed that the derived equation is applicable for scaling up the T-shaped mixers.
机译:工业化学生产过程中危险的磷脂反应的过程安全是一个关键问题。我们在本文中设计了一种紧凑的流动反应方法,用于phosgenation反应,并在商业厂成功安装了该系统。光气的载体显着降低,并在商业过程中纳入了泄漏检测系统。用于确定商业规模流量反应器的混合条件的扩展方法是本研究中最重要的任务。 Villermaux-Dushman反应用于评估T形混合器的混合性能与混合器出口直径,D_m范围为0.5×10〜(-3)至15.0×10〜(-3)m。通过Villermaux-Dushman反应溶液的吸光度确定了扩展条件。利用实验结果,获得了D_M的混合性能和流速的图。发现T形混合器中的流体段尺寸W_c(= D_m / 2〜(0.5)),混合器流量的雷诺数是用于在T形混合器中混合的重要参数。我们派生了混合性能与w_c / re〜n之间的相关性。发现本研究中使用的所有混合器与N值为1.19具有与1.19的相同的相关性。我们还证实,衍生的方程适用于缩放T形混合器。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号