首页> 外文期刊>The journal of asthma >Difference between two exhaled nitric oxide analyzers, NIOX VEROA (R) electrochemical hand-held analyzer and NOA280iA (R) chemiluminescence stationary analyzer
【24h】

Difference between two exhaled nitric oxide analyzers, NIOX VEROA (R) electrochemical hand-held analyzer and NOA280iA (R) chemiluminescence stationary analyzer

机译:两个呼出的一氧化氮分析仪之间的差异,NiOx Veroa(R)电化学手持分析仪和NOA280ia(R)化学发光静止分析仪

获取原文
获取原文并翻译 | 示例
           

摘要

Background: Fractional exhaled nitric oxide (FENO) is useful for the evaluation of eosinophilic airway inflammation, including that seen in asthma. Although a new electrochemical hand-held FENO analyzer, the NIOX VEROA (R) (Aerocrine AB, Solna, Sweden), is clinically convenient to use, it has not been fully compared with the chemiluminescence stationary electrochemical analyzer NOA280iA (R) (Sievers Instruments, Boulder, CO, USA) in terms of the level of measured FENO. The aim of this study was to determine whether there is a difference between the two analyzers. Methods: The FENO levels measured with both NIOX VEROA (R) and NOA280iA (R) were evaluated in 1,369 adults at Juntendo University Hospital from May 2016 to October 2016. Results: The median FENO level measured with the NIOX VEROA (R) was significantly lower than that measured with the NOA280iA (R) (41 ppb, range 5-368 ppb vs. 29 ppb, range 5-251 ppb; p < 0.001). There was a strong positive correlation in the measurement of FENO level between the NOA280i (R) and the NIOX VEROA (R) (r = 0.942, p < 0.001). The following conversion equation was calculated: FENO (NOA280iA (R)) = 1.362 (SE, 0.661) + 1.384 (SE, 0.021) x FENO (NIOX VEROA (R)). Conclusions: To our best knowledge, we have provided the first report showing that the measured FENO level with the NIOX VEROA (R) was approximately 30% lower than that with the NOA280iA (R) and that there was a significant correlation between the measurements of these two devices. The correction equation that we provided may help assess the data obtained by these two analyzers.
机译:背景:分数呼出的一氧化氮(FENO)可用于评估嗜酸性嗜酸性气道炎症,包括在哮喘中看到的。虽然新型电化学手持式FENO分析仪,NIOX VEROA(R)(瑞典,瑞典,SOSNA,SOWEN)在临床上使用,但它与化学发光固定电化学分析仪NOA280IA(R)(Sievers Instruments ,博尔德,CO,USA)在测量的FENO水平方面。本研究的目的是确定两个分析仪之间是否存在差异。方法:在2016年5月至2016年10月,在爪德多大学医院的1,369名成人中评估了用NiOx Veroa(R)和NOA280ia(R)测量的FENo水平。结果:用NIOx Veroa(R)测量的中位数级别明显低于NOA280ia(R)测量的(41ppb,5-368 ppb vs.29ppb,范围5-251ppb; p <0.001)。在NOA280i(R)和NiOx Veroa(R)之间的FENO水平测量中存在强烈的正相关性(R = 0.942,P <0.001)。计算以下转换方程:FENO(NOA280ia(R))= 1.362(SE,0.661)+ 1.384(SE,0.021)x FENO(NIOX Veroa(R))。结论:为了我们的最佳知识,我们提供了第一个报告,表明使用NIOX VEROA(R)的测量的FENO水平比NOA280IA(R)低约30%,并且测量之间存在显着相关性这两个设备。我们提供的校正方程可以有助于评估这两个分析仪获得的数据。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号