...
首页> 外文期刊>Journal of applied toxicology >Comparison of protocols measuring diffusion and partition coefficients in the stratum corneum
【24h】

Comparison of protocols measuring diffusion and partition coefficients in the stratum corneum

机译:比较岩层中的漫射扩散与分区系数的比较

获取原文
获取原文并翻译 | 示例

摘要

Partition (K) and diffusion (D) coefficients are important to measure for the modelling of skin penetration of chemicals through the stratum corneum (SC). We compared the feasibility of three protocols for the testing of 50 chemicals in our main studies, using three cosmetics-relevant model chemicals with a wide range of logP values. Protocol 1: SC concentration-depth profile using tape-stripping (measures K-SC/v and D-SC/H-SC(2), where H-SC is the SC thickness); Protocol 2A: incubation of isolated SC with chemical (direct measurement of K-SC/v only) and Protocol 2B: diffusion through isolated SC mounted on a Franz cell (measures K-SC/v and D-SC/H-SC 2, and is based on Fick's laws). K-SC/v values for caffeine and resorcinol using Protocol 1 and 2B were within 30% of each other, values using Protocol 2A were similar to two-fold higher, and all values were within 10-fold of each other. Only indirect determination of K-SC/v by Protocol 2B was different from the direct measurement of K-SC/v by Protocol 2A and Protocol 1 for 7-EC. The variability of K-SC/v for all three chemicals using Protocol 2B was higher compared to Protocol 1 and 2A. D-SC/H-SC 2 values for the three chemicals were of the same order of magnitude using all three protocols. Additionally, using Protocol 1, there was very little difference between parameters measured in pig and human SC. In conclusion, K-SC/v, and D-SC values were comparable using different-methods. Pig skin might be a good surrogate for human skin for the three chemicals tested. Copyright (C) 2017 The Authors Journal of Applied Toxicology published by John Wiley & Sons Ltd.
机译:分区(K)和扩散(D)系数对于通过Stratum Corneum(SC)测量化学物质的皮肤渗透建模是重要的。我们将三种协议的可行性与我们的主要研究中的50种化学品进行测试,使用三种化妆品相关的模型化学品,具有各种LOGP值。协议1:使用带式剥离的SC浓度深度曲线(测量K-SC / V和D-SC / H-SC(2),其中H-SC是SC厚度);协议2A:用化学物质(仅限K-SC / V的直接测量)和协议2B的分离SC孵育:通过安装在FRANZ细胞上的隔离SC的扩散(测量K-SC / V和D-SC / H-SC 2,并且是基于Fick的法律)。使用方案1和2B的咖啡因和间苯二酚的K-SC / V值彼此的30%,使用协议2A的值类似于较高的两倍,并且所有值彼此的10倍。通过协议2b的K-SC / V的间接测定与通过协议2a和6 eC的协议1的K-SC / V的直接测量不同。与协议1和2A相比,使用协议2B的所有三种化学品的K-SC / V的可变性更高。三种化学品的D-SC / H-SC 2值使用所有三种协议具有相同的数量级。另外,使用协议1,在猪和人体SC中测量的参数之间存在很小差异。总之,K-SC / V和D-SC值使用不同方法进行比较。猪皮可能是用于测试三种化学品的人体皮肤的良好替代品。版权所有(c)2017作者作者杂志杂志John Wiley&Sons Ltd.出版

著录项

  • 来源
    《Journal of applied toxicology》 |2017年第8期|共11页
  • 作者单位

    Procter &

    Gamble Serv GmbH Berliner Allee 65 D-64295 Darmstadt Germany;

    Procter &

    Gamble Inc Mason Business Ctr Mason OH 45040 USA;

    Procter &

    Gamble Inc Mason Business Ctr Mason OH 45040 USA;

    LOreal Res &

    Innovat 1 Ave Eugene Schueller F-93601 Aulnay Sous Bois France;

    LOreal Res &

    Innovat 1 Ave Eugene Schueller F-93601 Aulnay Sous Bois France;

    LOreal Res &

    Innovat 1 Ave Eugene Schueller F-93601 Aulnay Sous Bois France;

    Cosmet Europe Ave Herrmann Debroux 40 B-1160 Brussels Belgium;

    Unilever Colworth Sci Pk Sharnbrook MK44 1LQ Beds England;

    Pierre Fabre Dermo Cosmet 3 Ave Hubert Curien F-31035 Toulouse France;

    Beiersdorf AG Unnastr 48 D-20245 Hamburg Germany;

    Pierre Fabre Dermo Cosmet 3 Ave Hubert Curien F-31035 Toulouse France;

    Cosmet Europe Ave Herrmann Debroux 40 B-1160 Brussels Belgium;

    Beiersdorf AG Unnastr 48 D-20245 Hamburg Germany;

    LOreal Res &

    Innovat 1 Ave Eugene Schueller F-93601 Aulnay Sous Bois France;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 毒物学(毒理学);
  • 关键词

    diffusion; partition; coefficients; stratum corneum; protocols; comparison;

    机译:扩散;分区;系数;Stratum Corneum;协议;比较;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号