首页> 外文期刊>AJR: American Journal of Roentgenology : Including Diagnostic Radiology, Radiation Oncology, Nuclear Medicine, Ultrasonography and Related Basic Sciences >Interpretation of positron emission mammography and MRI by experienced breast imaging radiologists: performance and observer reproducibility.
【24h】

Interpretation of positron emission mammography and MRI by experienced breast imaging radiologists: performance and observer reproducibility.

机译:经验丰富的乳腺影像放射科医生对正电子发射乳腺摄影和MRI的解释:性能和观察者的可重复性。

获取原文
获取原文并翻译 | 示例
       

摘要

OBJECTIVE: In preparation for a multicenter trial of positron emission mammography (PEM) and MRI in women with newly diagnosed cancer, the two purposes of this study were to validate training of breast imagers in standardized interpretation of PEM and to validate performance of the same specialists interpreting MRI. MATERIALS AND METHODS: A 2-hour didactic module was developed to train Mammography Quality Standards Act-qualified radiologist observers to interpret PEM images, consisting of a sample feature analysis lexicon analogous to BI-RADS and 12 sample cases. Observers were then asked to review separate interpretive skills tasks for PEM (49 breasts, 20 [41%] of which were malignant) and MRI (32 breasts, 11 [34%] of which were malignant), describe findings, and give assessments analogous to BI-RADS (category 1, 2, 3, 4A, 4B, 4C, or 5). Demographic experience variables were collected for 36 observers from 15 sites. Performance against histopathologic truth was determined, and interobserver agreement for classifying features and final assessments was evaluated using kappa statistics. RESULTS: Across 36 observers, mean sensitivity, specificity, and area under the curve (AUC) for PEM were 96% (range, 75-100%), 84% (range, 66-97%), and 0.95 (range, 0.82-1.0), respectively. Mean sensitivity, specificity, and AUC for the MRI task were 82% (range, 45-100%), 67% (range, 38-91%), and 0.80 (range, 0.48-0.96), respectively. Interobserver agreement for PEM findings ranged from moderate to substantial, with kappa values of 0.57 for lesion type and 0.63 for final assessments. CONCLUSION: With minimal training, experienced breast imagers showed high performance in interpreting PEM images. Performance in MRI interpretation by the same observers validated expected clinical practice.
机译:目的:在准备对新诊断为癌症的女性进行正电子发射乳腺摄影(PEM)和MRI的多中心试验时,本研究的两个目的是验证对乳房成像仪进行PEM标准化解释的培训,并验证同一位专家的表现解释MRI。材料与方法:开发了一个2小时的教学模块,以训练符合X线摄影质量标准法案要求的放射线医师观察员来解释PEM图像,其中包括类似于BI-RADS的样本特征分析词典和12个样本案例。然后要求观察者复查PEM(49个乳房,其中20个[41%]为恶性)和MRI(32个乳房,其中11个[34%]为恶性)的单独解释技能任务,描述发现并进行类似评估到BI-RADS(1、2、3、4A,4B,4C或5类)。收集了来自15个地点的36位观察员的人口统计学变量。确定针对组织病理学事实的表现,并使用kappa统计量评估观察者之间对特征分类和最终评估的一致性。结果:在36位观察者中,PEM的平均敏感性,特异性和曲线下面积(AUC)分别为96%(范围75-100%),84%(范围66-97%)和0.95(范围0.82) -1.0)。 MRI任务的平均敏感性,特异性和AUC分别为82%(范围45-100%),67%(范围38-91%)和0.80(范围0.48-0.96)。观察者之间对PEM发现的一致性从中等到严重不等,病变类型的kappa值为0.57,最终评估的kappa值为0.63。结论:经过最少的培训,经验丰富的乳房成像人员在解释PEM图像方面表现出了很高的性能。相同观察者在MRI解释中的表现验证了预期的临床实践。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号