首页> 外文期刊>Human movement science >Minimal detectable change of kinematic and spatiotemporal parameters in patients with chronic stroke across three sessions of gait analysis
【24h】

Minimal detectable change of kinematic and spatiotemporal parameters in patients with chronic stroke across three sessions of gait analysis

机译:步态分析三次会话慢性中风患者运动学和时空参数的最小可检测变化

获取原文
获取原文并翻译 | 示例
           

摘要

Three-dimensional gait analysis is the gold standard for gait-assessment in patients with stroke. This technique is commonly used to assess the effect of treatment on gait parameters. In clinical practice, three gait analyses are usually carried out (baseline, after treatment and follow-up), the objectives were to define the reproducibility and the Minimum Detectable Change (MDC) for gait parameters in stance and swing measured using 3D-gait analysis, and to assess changes in MDC across three repeated 3D-gait analyses. Three gait analyses (V1, V2 and V3) were performed at 7-day intervals in twenty-six patients with chronic stroke. Kinematic data (in the sagittal plane, during swing and stance) and spatiotemporal data were evaluated for the paretic limb. Reliability was tested using repeated measures ANOVA with a Tukey post hoc test, and the MDC values were calculated for each parameter. Only the range of hip motion during swing changed significantly between V1 and V2, but no other kinematic parameters changed. No significant differences were observed for the spatiotemporal parameters. MDC values were always higher during the VlvsV2 comparison for both kinematic and spatiotemporal parameters. This is the first study to evaluate the MDC for kinematic and spatiotemporal parameters during stance and swing. Reliability of kinematic and spatiotemporal data across sessions was very good over the three sessions. MDC values were the lowest between V2 and V3 for most parameters. Use of the MDC will allow clinicians to more accurately determine the effect of treatments.
机译:三维步态分析是中风患者的步态评估金标准。该技术通常用于评估治疗对步态参数的影响。在临床实践中,通常进行三个步态分析(基线,治疗和随访后基线),目的是定义使用3D-Gait分析测量的姿态和摆动中的步态参数的再现性和最小可检测变化(MDC) ,并评估跨三个重复的3D-Gait分析的MDC的变化。在二十六名慢性卒中患者中,在7天间隔进行三次步态分析(V1,V2和V3)。对瘫痪的肢体评估了运动数据(在矢状平面,在矢状平面)和时空数据。使用具有Tukey Post Hoc测试的重复测量Anova测试可靠性,为每个参数计算MDC值。在v1和v2之间,摆动期间的臀部运动范围显着变化,但没有改变其他运动参数。对于时空参数,没有观察到显着差异。在VLVSv2的VLVSv2比较期间MDC值始终较高,适用于运动学和时空参数。这是第一次研究在姿势和摆动期间评估运动学和时空参数的MDC。在三个会议上,跨会话的运动和时空数据的可靠性非常好。 MDC值是V2和V3之间最低的最低参数。使用MDC将使临床医生能够更准确地确定治疗的效果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号