首页> 外文期刊>AJNR. American journal of neuroradiology >High-resolution MRI of the intraparotid facial nerve based on a microsurface coil and a 3d reversed fast imaging with steady-state precession DWI sequence at 3T
【24h】

High-resolution MRI of the intraparotid facial nerve based on a microsurface coil and a 3d reversed fast imaging with steady-state precession DWI sequence at 3T

机译:基于微表面线圈和3d稳态进动DWI序列的3d反向快速成像,对腮腺面神经进行高分辨率MRI

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND AND PURPOSE: 3D high-resolution MR imaging can provide reliable information for defining the exact relationships between the intraparotid facial nerve and adjacent structures. The purpose of this study was to explore the clinical value of using a surface coil combined with a 3D-PSIF-DWI sequence in intraparotid facial nerve imaging. MATERIALS AND METHODS: Twenty-one healthy volunteers underwent intraparotid facial nerve scanning at 3T by using the 3D-PSIFDWI sequence with both the surface coil and the head coil. Source images were processed with MIP and MPR to better delineate the intraparotid facial nerve and its branches. In addition, the SIR of the facial nerve and parotid gland was calculated. The number of facial nerve branches displayed by these 2 methods was calculated and compared. RESULTS: The display rates of the main trunk, divisions (cervicofacial, temporofacial), and secondary branches of the intraparotid facial nerve were 100%, 97.6%, and 51.4% by head coil and 100%, 100%, and 83.8% by surface coil, respectively. The display rate of secondary branches of the intraparotid facial nerve by these 2 methods was significantly different (P = .05). The SIRs of the intraparotid facial nerve/parotid gland in these 2 methods were significantly different (P = .05) at 1.37 = 1.06 and 1.89 = 0.87, respectively. CONCLUSIONS: The 3D-PSIF-DWI sequence combined with a surface coil can better delineate the intraparotid facial nerve and its divisions than when it is combined with a head coil, providing better image contrast and resolution. The proposed protocol offers a potentially useful noninvasive imaging sequence for intraparotid facial nerve imaging at 3T.
机译:背景与目的:3D高分辨率MR成像可提供可靠的信息,用于定义腮腺内面神经与相邻结构之间的确切关系。这项研究的目的是探讨将表面线圈与3D-PSIF-DWI序列结合使用在腮腺面神经成像中的临床价值。材料与方法:21名健康志愿者通过使用3D-PSIFDWI序列以及表面线圈和头部线圈在3T下进行腮腺内面神经扫描。用MIP和MPR处理源图像,以更好地描绘腮腺内面神经及其分支。此外,还计算了面神经和腮腺的SIR。计算并比较了这两种方法显示的面神经分支的数量。结果:腮腺面神经的主干,分区(颈面部,颞面部)和次要分支的显示率分别为100%,97.6%和51.4%(头线圈),表面分别为100%,100%和83.8%。线圈。这两种方法对腮腺内面神经次要分支的显示率有显着差异(P = 0.05)。在这两种方法中,腮腺内面神经/腮腺的SIR分别显着不同(P = .05),分别为1.37 = 1.06和1.89 = 0.87。结论:3D-PSIF-DWI序列与表面线圈相结合比与头部线圈相结合能更好地描绘腮腺内面神经及其分裂,从而提供更好的图像对比度和分辨率。提出的协议为3T腮腺内面神经成像提供了潜在有用的非侵入性成像序列。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号