首页> 外文期刊>AJR: American Journal of Roentgenology : Including Diagnostic Radiology, Radiation Oncology, Nuclear Medicine, Ultrasonography and Related Basic Sciences >Benign predominantly solid thyroid nodules: prospective study of efficacy of sonographically guided radiofrequency ablation versus control condition.
【24h】

Benign predominantly solid thyroid nodules: prospective study of efficacy of sonographically guided radiofrequency ablation versus control condition.

机译:良性甲状腺实性结节:超声引导下射频消融疗效与对照情况的前瞻性研究。

获取原文
获取原文并翻译 | 示例
           

摘要

OBJECTIVE: The purpose of this study was to evaluate the efficacy of radiofrequency ablation of benign predominantly solid thyroid nodules by comparing the findings in treatment and control groups. SUBJECTS AND METHODS: Thirty patients with normal thyroid function, each with a benign predominantly (> 50%) solid thyroid nodule causing pressure symptoms or cosmetic problems, were assigned to a control group (n = 15) or to a group undergoing a single session of radiofrequency ablation (n = 15). Thyroid nodule volume, thyroid function, pressure symptoms, and cosmetic concerns were evaluated before treatment and during follow-up. Sonographically guided radiofrequency ablation was performed with an internally cooled electrode (1-cm active tip) with an output power of 30-80 W. RESULTS: The control group had no resolution of symptoms or cosmetic problems. The mean nodule volume increased slightly after 6 months but without statistical significance (p = 0.46). In the radiofrequency ablation group, the mean symptom score (p = 0.001) and cosmetic grade (p = 0.001) improved significantly. Mean nodule volume decreased significantly from 7.5 +/- 4.9 mL (range, 1.7-20.0 mL) to 1.3 +/- 0.8 mL (range, 0.2-2.6 mL) 6 months after radiofrequency ablation (p = 0.001). There were no major complications of ablation. CONCLUSION: This study confirmed that radiofrequency ablation is effective for reducing nodule volume and relieving nodule-related clinical problems and that an effect due to spontaneous nodule reduction can be excluded owing to the results of the comparison with a similar control group.
机译:目的:本研究的目的是通过比较治疗组和对照组的结果来评估射频消融对良性甲状腺实性结节的疗效。研究对象和方法:将30例甲状腺功能正常的患者(每个患者良性(> 50%)实性甲状腺结节引起压力症状或美容问题)分配为对照组(n = 15)或接受单次治疗的组射频消融的次数(n = 15)。治疗前和随访期间评估了甲状腺结节的体积,甲状腺功能,压力症状和美容问题。超声引导下的射频消融是使用内部冷却的电极(1厘米的活动尖端)进行的,输出功率为30-80W。结果:对照组没有症状或美容问题的解决方案。 6个月后,平均结节体积略有增加,但无统计学意义(p = 0.46)。在射频消融组中,平均症状评分(p = 0.001)和美容等级(p = 0.001)明显改善。射频消融后6个月,平均结节体积从7.5 +/- 4.9 mL(范围1.7-20.0 mL)显着降低至1.3 +/- 0.8 mL(范围0.2-2.6 mL)(p = 0.001)。没有重大的消融并发症。结论:这项研究证实射频消融对减少结节体积和缓解结节相关的临床问题是有效的,并且由于与相似对照组比较的结果,自发结节减少所引起的影响可被排除。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号