...
首页> 外文期刊>The International journal of prosthodontics >Two-Implant-Supported Mandibular Overdentures: Do Clinical Denture Quality and Inter-Implant Distance Affect Patient Satisfaction?
【24h】

Two-Implant-Supported Mandibular Overdentures: Do Clinical Denture Quality and Inter-Implant Distance Affect Patient Satisfaction?

机译:双植入的下颌覆盖:临床义齿质量和植入间距影响患者满意度吗?

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Purpose: To investigate the following three null hypotheses in patients rehabilitated with a mandibular overdenture supported by two unsplinted implants: (1) patient satisfaction is not related to the clinical quality of the dentures; (2) inter-implant distance (IID) has no effect on the clinical quality of the dentures; and (3) IID does not influence patient satisfaction. Materials and Methods: Forty edentulous patients who were rehabilitated with a two-implant-supported mandibular overdenture participated in the study. Independent investigators evaluated the dentures on the basis of five clinical criteria using the validated Denture Quality Evaluation Form, and the patients completed the validated Denture Satisfaction Scale. Irreversible hydrocolloid impressions of the mandible were made and poured immediately in die stone. The IID was measured by adapting an orthodontic wire to the mandibular alveolar ridge crest, extending from the center of one implant to the center of the other. Spearman correlation analyses were used to identify possible correlations, with a significance level set at P<.05. Results: The clinicians' overall mean rating of the clinical quality of the dentures was 91.5% (standard deviation 6.27%). The stability of the mandibular overdenture and of the maxillary conventional complete denture was significantly related to satisfaction (r=0.389 and r=0.44, respectively). Significant associations were found between the mandibular stability items and satisfaction with both maxillary and mandibular dentures. The stability of the maxillary denture was significantly associated with patient satisfaction with mandibular denture retention, stability, and comfort. None of the 12 denture satisfaction items were significantly associated with IID. Similarly, IID did not have an effect on the quality of either denture in terms of retention, stability, or occlusion. Conclusion: Denture stability was the feature that had the most influence on patient satisfaction with the mandibular overdenture and with the maxillary conventional denture. IID had no effect on the clinical quality of either denture and did not influence patient satisfaction.
机译:目的:探讨患有由两种未录合植入物支持的下颌过度恢复的患者中的以下三个零假设:(1)患者满意与义齿的临床质量无关; (2)植入间距离(IID)对假牙的临床质量没有影响; (3)IID不会影响患者满意度。材料和方法:用双植入的颌骨覆盖恢复的四十次薄弱患者参与了该研究。独立调查人员使用经过验证的假牙质量评估表的五个临床标准评估假牙,并且患者完成了验证的义齿满意度规模。不可逆转的水致印迹印刷的印象是在模具石头中立即进行的。通过将正畸线适应下颌肺泡脊嵴来测量IID,从一个植入物到另一个植入中心延伸到另一个植入物的中心。 SPEARMAN相关分析用于识别可能的相关性,具有在P <0.05处设定的显着水平。结果:临床医生的临床质量的总体平均额定值为91.5%(标准偏差6.27%)。下颌覆盖和上颌常规完整义齿的稳定性与满意度显着相关(分别为r = 0.389和r = 0.44)。在下颌稳定性物质和颌骨和下颌假牙的下颌稳定性物质和满足之间发现了显着的关联。上颌义齿的稳定性与患者满意度显着与下颌义齿保留,稳定性和舒适性有关。 12个义齿满足物品中没有一个与IID显着相关。同样,IID在保留,稳定性或闭塞方面没有对义齿的质量产生影响。结论:义齿稳定性是对患者满意度影响的特征是与下颌覆盖和上颌常规义齿产生影响。 IID对义齿的临床质量没有影响,并没有影响患者满意度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号