首页> 外文期刊>The International journal of periodontics & restorative dentistry >Crestal Bone and Keratinized Tissue Around 3.0-mm Laser-Microtextured Dental Implants After 1 Year in Function: A Case Series
【24h】

Crestal Bone and Keratinized Tissue Around 3.0-mm Laser-Microtextured Dental Implants After 1 Year in Function: A Case Series

机译:冠状骨和角化组织约3.0毫米激光 - 微直箱牙科植入物在1年后的功能:一个案例系列

获取原文
获取原文并翻译 | 示例
           

摘要

The purpose of this case series was to evaluate peri-implant tissues in 10 patients at 1 year after placement of a tapered 3.0-mm laser-microtextured dental implant (Laser-Lok, BioHorizons) using a two-stage approach. Clinical and radiographic measurements were assessed. Keratinized tissue at the facial surfaces of each implant had slight increase of a 0.73 mm (95% confidence interval [CI],P = .058), and marginal bone levels had significant increase of 1.85 mm (95% CI, P = .005) at 1 year compared to baseline. These data suggest that 3.0-mm laser-microtextured implants demonstrate stable or improved soft and hard tissue parameters at 1 year postloading.
机译:本案例系列的目的是在使用两阶段方法在放置锥形3.0mm激光 - 微直箱牙齿植入物(激光-Lok,生物健ol)后1年内评估10名患者的Peri-inclantant组织。 评估临床和放射线摄影测量。 每个植入物的面部表面的角化组织略有增加0.73mm(95%置信区间[CI],P = .058),边际骨水平显着增加1.85毫米(95%CI,P = .005 )与基线相比的1年。 这些数据表明,3.0毫米激光 - 微织物植入物在1年的发电机上展示稳定或改善的软和硬组织参数。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号