A multidisciplinary quality improvement program increases the inferior vena cava filter retrieval rate

机译:多学科质量改进计划增加了下腔静脉滤波器检索率

获取原文
获取原文并翻译 | 示例
       

摘要

Published reports indicate low retrieval rates for retrievable inferior vena cava (IVC) filters. We performed a historic-controlled study of a 5-year intervention (March 2007 to February 2012) to improve IVC filter retrieval rates at a university medical center serving a rural area. All adults with a retrievable filter placed were included, except those with a life expectancy <6 months. The intervention included initial verbal counseling and printed educational materials, correspondence after discharge, and a hematology consultation. The control group included patients with retrievable filters placed in the 15 months preceding study initiation. In the control group, 116 filters were placed and 27 (23%) were removed, compared to 378 filters placed and 169 (45%) removed during the intervention. Adjusting for patient characteristics, the odds ratio of retrieval during the intervention was 3.03 (95% CI 1.85-4.27) compared to the control period. An intervention including patient education and hematology follow-up appeared to significantly improve IVC filter retrieval rates.
机译:已发表的报告表示可检索的下腔静脉(IVC)过滤器的低检索速率。我们对5年干预(2007年3月至2012年3月)进行了历史性控制研究,以改善在农村地区提供的大学医疗中心的IVC过滤器检索率。除了寿命预期<6个月外,还包括可检索过滤器放置的所有成年人。干预包括初始口头咨询和印刷教育材料,放电后的通信和血液学咨询。该对照组包括在前一项研究开始的15个月内置于可检索过滤器的患者。在对照组中,将116个过滤器置于置位,除去27(23%),与378个过滤器相比,在干预期间除去169(45%)。调整患者特征,与控制期相比,干预过程中检索的差距为3.03(95%CI 1.85-4.27)。在包括患者教育和血液学随访的干预似乎显着提高了IVC过滤器检索率。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号