首页> 外文期刊>AJNR. American journal of neuroradiology >In vitro and in vivo imaging characteristics assessment of polymeric coils compared with standard platinum coils for the treatment of intracranial aneurysms
【24h】

In vitro and in vivo imaging characteristics assessment of polymeric coils compared with standard platinum coils for the treatment of intracranial aneurysms

机译:聚合物线圈与标准铂线圈在颅内动脉瘤治疗中的体外和体内成像特性评估

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

BACKGROUND AND PURPOSE: Conventional platinum coils cause imaging artifacts that reduce imaging quality and therefore impair imaging interpretation on intraprocedural or noninvasive follow-up imaging. The purpose of this study was to evaluate imaging characteristics and artifact production of polymeric coils compared with standard platinum coils in vitro and in vivo. MATERIALS AND METHODS: Polymeric coils and standard platinum coils were evaluated in vitro with the use of 2 identical silicon aneurysm models coiled with a packing attenuation of 20% each. DSA, flat panel CT, CT, and MR imaging were performed. In vivo evaluation of imaging characteristics of polymeric coils was performed in experimentally created rabbit carotid bifurcation aneurysms. DSA, CT/CTA, and MR imaging were performed after endovascular treatment of the aneurysms. Images were evaluated regarding visibility of individual coils, coil mass, artifact production, and visibility of residual flow within the aneurysm. RESULTS: Overall, in vitro and in vivo imaging showed relevantly reduced artifact production of polymeric coils in all imaging modalities compared with standard platinum coils. Image quality of CT and MR imaging was improved with the use of polymeric coils, which permitted enhanced depiction of individual coil loops and residual aneurysm lumen as well as the peri-aneurysmal area. Remarkably, CT images demonstrated considerably improved image quality with only minor artifacts compared with standard coils. On DSA, polymeric coils showed transparency and allowed visualization of superimposed vessel structures. CONCLUSIONS: This initial experimental study showed improved imaging quality with the use of polymeric coils compared with standard platinum coils in all imaging modalities. This might be advantageous for improved intraprocedural imaging for the detection of complications and posttreatment noninvasive follow-up imaging.
机译:背景与目的:传统的铂金线圈会导致成像伪影,从而降低成像质量,因此会损害过程内或无创随访成像的成像解释。这项研究的目的是在体外和体内评估聚合物线圈与标准铂线圈相比的成像特性和伪影产生。材料与方法:聚合物线圈和标准铂线圈在体外进行了评估,使用了两个相同的硅动脉瘤模型,每个模型的盘绕衰减为20%。进行了DSA,平板CT,CT和MR成像。在实验创建的兔颈动脉分叉动脉瘤中进行了聚合物线圈成像特性的体内评估。在血管内治疗动脉瘤后进行DSA,CT / CTA和MR成像。评估了有关单个线圈的可见性,线圈质量,伪影产生以及动脉瘤内残留血流的可见性的图像。结果:与标准铂线圈相比,在所有成像方式中,总体而言,体外和体内成像显示聚合物线圈的假象产生显着减少。使用聚合物线圈可以改善CT和MR成像的图像质量,从而可以增强单个线圈环和残留动脉瘤腔以及动脉瘤周围区域的描绘。值得注意的是,与标准线圈相比,CT图像显示出只有少量伪影的显着改善的图像质量。在DSA上,聚合物线圈显示透明性,并可以观察叠加的血管结构。结论:这项初步的实验研究表明,在所有成像方式中,与标准铂金线圈相比,使用聚合物线圈提高了成像质量。这对于改进用于检查并发症的过程内成像和治疗后无创随访成像可能是有利的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号