首页> 外文期刊>Veterinary and Comparative Orthopaedics and Traumatology >Repeatability of Three-Dimensional Computed Tomographic Volumetric Measurement of Lumbosacral Intervertebral Foramina in German Shepherd Dogs
【24h】

Repeatability of Three-Dimensional Computed Tomographic Volumetric Measurement of Lumbosacral Intervertebral Foramina in German Shepherd Dogs

机译:德国牧羊犬腰椎间椎间盘的三维计算断层体积测量的可重复性

获取原文
获取原文并翻译 | 示例
           

摘要

Objectives This article determines the repeatability of a recently reported method of volumetric measurement of the lateral intervertebral neurovascular foramina at the lumbosacral junction in German shepherd dogs. Materials and Methods Batch files including the intervertebral neurovascular foramina were derived from previously obtained computed tomography studies of the extended lumbosacral junction of 20 German shepherd dogs and converted into volume datasets. Three observers independently performed five measurements of the left and right lumbosacral intervertebral neurovascular foramina in each dog, using an Extended Brilliance Workstation (Phillips, The Netherlands) to generate a volume of the lumbosacral intervertebral foramina in cubic millimetres, as described by Worth and colleagues in 2017. The inter-observer repeatability of the mean of the five-volume measurements (40 foramina) was assessed using the Bland–Altman limits of agreement method. One observer, blinded to the previous measurements, repeated the volumetric analysis on 20 lumbosacral intervertebral foramina for an assessment of intra-observer repeatability using the same statistical methods. Results This method of volumetric analysis showed good intra- and inter-observer repeatability with 95% of paired comparisons falling within two standard deviations of the mean difference between them. Clinical Significance This method of measuring the volume of the lumbosacral intervertebral neurovascular foramina is repeatedly reliable and may be a useful tool when testing the effects of motion and disease on the lumbosacral junction, and could help guide surgical intervention when foraminal narrowing is implicated in the clinical signs.
机译:目的本文确定了德国牧羊犬腰骶交界处的横向椎间体血管围巾的最近报告的体积测量方法的可重复性。材料和方法包括椎间体血管孢子的批量文件来自先前获得的德国牧羊犬的延长腰骶交界处的先前获得的计算断层扫描研究,并转换成体积数据集。三个观察者独立地进行了每只狗的左右腰骶椎体血管孢子的五次测量,使用扩展的亮度工作站(北荷兰)来产生立方毫米的腰骶部椎间囊的体积,如值得和同事所描述的2017年,使用协议方法的Bland-Altman限制评估了五卷测量(40个Foramina)的平均值的观察者间可重复性。一个观察者,蒙蔽了先前的测量,重复了对20 lembosacral椎间孔的体积分析,用于使用相同的统计方法评估观察者内部的重复性。结果该体积分析方法显示出良好的内部和观察者间可重复性,其成对比较的95%落在它们之间平均差异的两个标准偏差范围内。临床意义这种测量腰骶神经血管孢子的体积的方法是多次可靠的,并且在测试运动和疾病对腰骶交界处的影响时可能是一种有用的工具,并且当临床中涉及致盲声缩小时可能有助于导致手术干预标志。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号