...
首页> 外文期刊>Veterinary and Comparative Oncology >Inter‐ and intra‐rater reliability and agreement in determining subcutaneous tumour margins in dogs
【24h】

Inter‐ and intra‐rater reliability and agreement in determining subcutaneous tumour margins in dogs

机译:在患有狗的皮下肿瘤边缘的间间和帧内帧内的可靠性和协议

获取原文
获取原文并翻译 | 示例
           

摘要

The objective of this prospective study was to evaluate agreement and reliability of calliper‐based measurements of locally invasive subcutaneous malignant tumours in dogs. Four raters measured the longest diameter of 12 subcutaneous tumours (7 soft tissue sarcomas and 5 mast cell tumours) from 11 client‐owned dogs during 3 randomized, blinded measurement trials, both pre‐ and post‐sedation. Inter‐ and intra‐rater reliability was evaluated using intra‐class correlation coefficient (ICC) and agreement was evaluated using Bland‐Altman plots. Inter‐ and intra‐rater reliability was good (ICC range of 0.8694‐0.89520) and excellent (ICC range of 0.9720‐0.9966), respectively. For agreement calculations, an a priori clinically relevant limit of agreement of 10 mm was set. Inter‐ and intra‐rater agreement was unacceptable with inter‐rater limits of agreement ranging from 15.9 to 55.6 mm and intra‐rater limit of agreement ranging from 11.9 to 28.1 mm. Review of the measurement trial photographs revealed that calliper orientation changes were frequent, occurring in 9/12 (75%) and 8/12 (67%) pre‐ and post‐sedation cases. No significant correlation was found between inter‐rater measurement standard deviations and calliper orientation changes or dog body condition score. These findings suggest veterinarians may have poor agreement in determining the gross edge of tumours, which is expected to introduce bias and inconsistency in tumour staging, assessing response to therapy, and surgical margin planning. Due to the potential consequences for veterinary cancer patients, future studies are needed to validate the present findings.
机译:该前瞻性研究的目的是评估狗局部侵入性皮下恶性肿瘤的基于卡尺的测量的一致性和可靠性。在3个随机盲化的测量试验期间,四个评估者测量了来自11名盲目的测量试验的11名盲目的测量试验中的12个皮下肿瘤(7软组织肉瘤和5幅肥大细胞肿瘤)。使用级别的相关系数(ICC)评估了帧内帧内的可靠性,并使用Bland-Altman Plots评估协议。帧内和帧内间可靠性好(ICC范围为0.8694-0.89520),优异的(ICC范围为0.9720-0.9966)。对于协议计算,设定了10毫米的先验临床相关限额。与帧内间协议的间际和内部协议不可接受,范围从15.9%到55.6毫米和评价者内限额,范围从11.9到28.1毫米。审查测量试验照片显示,Calliper取向变化频繁,发生在9/12(75%)和8/12(67%)前后和后后病例。在帧间测量标准偏差和卡尺方向变化或狗身份条件得分之间没有发现显着的相关性。这些调查结果表明兽医在确定肿瘤的总边缘方面可能具有较差的协议,这预计将引入肿瘤分期,评估对治疗的反应和外科保证金规划的偏见和不一致。由于对兽医癌患者的潜在后果,需要进行未来的研究来验证现在的研究结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号