首页> 外文期刊>Valve World >The bolted connection - seal failure analysis and corrective action
【24h】

The bolted connection - seal failure analysis and corrective action

机译:螺栓连接 - 密封故障分析和纠正措施

获取原文
获取原文并翻译 | 示例
           

摘要

As was discussed in our column in the February issue of Valve World, preventive and corrective actions are needed to minimize seal failures and subsequent down times. In this article, possible causes, checks and remedial actions are discussed. In general, seal failure shows itself as one of three relatively distinct failure modes; an immediate or sudden 'catastrophic' usually gross leak also known as a "blow out", a slow 'progressive' or chronic leak or a 'transient' leak that may occur for a time then self seal and may subsequently reoccur.
机译:正如我们在2月份的栏目中讨论的阀门世界,需要预防和纠正措施以最大限度地减少密封失败并随后停下来。 在本文中,讨论了可能的原因,检查和补救措施。 通常,密封失败显示为三种相对不同的失效模式之一; 立即或突然的“灾难性”通常泄漏又称“吹出”,缓慢的“进步”或慢性泄漏或可能发生的时间泄漏,这可能发生在自我密封的时间内,并且可以随后再次进行。