首页> 外文期刊>Valve World >High torques in dynamic flow conditions on wedge gate valves
【24h】

High torques in dynamic flow conditions on wedge gate valves

机译:楔形闸阀动态流动条件下的高扭矩

获取原文
获取原文并翻译 | 示例
           

摘要

The application of the Optimov program to some of our customer plants revealed that some families of wedge gate valves require higher torques in dynamic flow conditions than historically assumed. Valves inspections revealed that these high torques are caused by poor manufacturing processes of these valves. The Disc Factor of these valves was corrected through statistical analysis. The issue was solved through increase of the torque switch settings and replacement of the actuators of these wedge gate valves when needed.
机译:Optimov计划的应用于我们的一些客户厂揭示了一些楔形栅极阀门的家庭在动态流动条件下需要更高的扭矩,而不是历史上的假设。 阀门检查显示,这些高扭矩是由这些阀门的制造过程差而引起的。 通过统计分析校正这些阀的光盘因子。 通过扭矩开关设置的增加和在需要时更换这些楔形栅极阀的执行器来解决问题。

著录项

  • 来源
    《Valve World》 |2017年第6期|共2页
  • 作者

    Alexandre Neve;

  • 作者单位

    Tractebel;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng